Exeter/23 July 2013

From 2013.igem.org

(Difference between revisions)
Line 38: Line 38:
|}
|}
-
The working liquid cultures (NP7, NP8, Promoter + RBS, RBS, OmpR "A" and RBS + cph8) were NanoDropped, then had their concentrations increased using the SureClean protocol from 17/7/13.
+
The working liquid cultures (NP7, NP8, Promoter + RBS, RBS, OmpR "A" and RBS + cph8) were MiniPrepped, then NanoDropped, then had their concentrations increased using the SureClean protocol from 17/7/13. Each culture was replicated twice.
 +
 
 +
{| class="wikitable"
 +
|-
 +
! Part !! NanoDrop data (ng/ul) !! NanoDrop data after SureClean protocol (ng/ul)
 +
|-
 +
| Promoter and RBS #1 || 3.5 || 107.3
 +
|-
 +
| Promoter and RBS #2 || 2.1 || 107.3
 +
|-
 +
| NP8 #1 || 4.5 || 113.3
 +
|-
 +
| NP8 #2 || 5.9 || 40.1
 +
|-
 +
| RBS (BBa_B0034) #1 || 14.0 || 64.8
 +
|-
 +
| RBS (BBa_B0034) #2 || 2.2 || Would not pellet, SureClean failed
 +
|-
 +
| NP7 #1 || 35.5 || SureClean not required
 +
|-
 +
| NP7 #2 || 29.3 || Example
 +
|-
 +
| Example || Example || Example
 +
|-
 +
| Example || Example || Example
 +
|}

Revision as of 11:11, 25 July 2013

Unfortunately, some of our liquid cultures from yesterday appear to have not worked.

Also, the liquid cultures for OmpR and the OmpR promoter were mislabelled, so we're uncertain which is which. However, when we run "OmpR A" on a gel, it should be very obvious which is which, as OmpR is 917bp and the OmpR promoter is 108bp.

Part Did it work? Source
NP1 (CcaS + Terminator) Transformation plate
NP2 (promoter, RBS, FixJ + Terminator Transformation plate
NP3 (yellow pigment + Terminator) Transformation plate
NP4 (magenta pigment + Terminator) Transformation plate
NP7 (YF1 + Terminator) Transformation plate
NP8 (FixJ + Terminator) Transformation plate
Ligation control Transformation plate
Lambda inverter system Streak plate in fridge
T7 promoter Streak plate in fridge
Promoter + RBS (BBa_K608002) Streak plate in fridge
RBS (BBa_B0034) Streak plate in fridge
OmpR "A" Streak plate in fridge
OmpR "B" Streak plate in fridge
RFP control Transformation plate
RBS + cph8 (BBa_K592018) Transformation plate

The working liquid cultures (NP7, NP8, Promoter + RBS, RBS, OmpR "A" and RBS + cph8) were MiniPrepped, then NanoDropped, then had their concentrations increased using the SureClean protocol from 17/7/13. Each culture was replicated twice.

Part NanoDrop data (ng/ul) NanoDrop data after SureClean protocol (ng/ul)
Promoter and RBS #1 3.5 107.3
Promoter and RBS #2 2.1 107.3
NP8 #1 4.5 113.3
NP8 #2 5.9 40.1
RBS (BBa_B0034) #1 14.0 64.8
RBS (BBa_B0034) #2 2.2 Would not pellet, SureClean failed
NP7 #1 35.5 SureClean not required
NP7 #2 29.3 Example
Example Example Example
Example Example Example