Then run the PCR samples on a 1% agarose gel to verify the success of the reactions (each sample is prepared with 8µl of PCR reaction and 2µl of 6X loading die; 1kb ladder is good).
Then run the PCR samples on a 1% agarose gel to verify the success of the reactions (each sample is prepared with 8µl of PCR reaction and 2µl of 6X loading die; 1kb ladder is good).
</html>|pSB1C3-linearization-PCR}}
</html>|pSB1C3-linearization-PCR}}
 +
 +
{{:Team:UNITN-Trento/Templates/Styles/ProtocolSpoiler|Ethylene detection through Micro GC|<html>
 +
<p>
 +
An overnight culture was diluited 1:100 and grown until O.D.600 reached 0.5. After that, the culture was induced with 5 mM arabinose and placed with a stirrer in a sealed vial (V = 15 ml) with a pierceable septum. The sample was kept for about 4 hours at 37 &deg;C in thermoshaker. After that the sample was connected to the Micro Gas Chromatograph Agilent 3000A endowed with two colums: a Mol Sieve 5A Plot and a Plot U
 +
column (see the tables for colums and method specifications).
 +
</p>
 +
<table class="tn-sp-table">
 +
<TR>
 +
<th>
 +
Column
 +
</th>
 +
<th>
 +
Lenght
 +
</th>
 +
<th>
 +
Diameter
 +
</th>
 +
</TR>
 +
<tr>
 +
<td>
 +
Mol Sieve 5A Plot
 +
</td>
 +
<td>
 +
10 m
 +
</td>
 +
<td>
 +
0.32 mm
 +
</td>
 +
</tr>
 +
<tr>
 +
<td>
 +
Plot U
 +
</td>
 +
<td>
 +
8 m
 +
</td>
 +
<td>
 +
0.32 mm
 +
</td>
 +
</tr>
 +
</table>
 +
<table class="tn-sp-table">
 +
<tr>
 +
<th colspan = '2'>
 +
Method used
 +
</th>
 +
</tr>
 +
<tr>
 +
<th>
 +
t sample
 +
</th>
 +
<td>
 +
50 &deg;C
 +
</td>
 +
</tr>
 +
<tr>
 +
<th>
 +
t injector
 +
</th>
 +
<td>
 +
55 &deg;C
 +
</td>
 +
</tr>
 +
<tr>
 +
<th>
 +
t column Mol Sieve 5A Plot
 +
</th>
 +
<td>
 +
110 &deg;C
 +
</td>
 +
</tr>
 +
<tr>
 +
<th>
 +
t column Plot U
 +
</th>
 +
<td>
 +
70 &deg;C
 +
</td>
 +
</tr>
 +
<tr>
 +
<th>
 +
p column Mol Sieve 5A Plot
 +
</th>
 +
<td>
 +
39.16 psi
 +
</td>
 +
</tr>
 +
<tr>
 +
<th>
 +
p column Plot U
 +
</th>
 +
<td>
 +
21.76 psi
 +
</td>
 +
</tr>
 +
<tr>
 +
<th>
 +
t injection
 +
</th>
 +
<td>
 +
40 us
 +
</td>
 +
</tr>
 +
<tr>
 +
<th>
 +
t analysis
 +
</th>
 +
<td>
 +
95 s
 +
</td>
 +
</tr>
 +
</table>
 +
A measure was then taken.<br/>
 +
In order to estimate how much gas was taken for each measurement using the settings
 +
described above, a mass flow meter was connected to the micro GC.
 +
During a measurment, a flow of 3 (± 0.15) ml / min was registered. Due to the fact that a
 +
measurment lasts 10 s, the withdrawn volume was 0.5 ml.
 +