Team:Grenoble-EMSE-LSU/Project/Modelling/Building

From 2013.igem.org

(Difference between revisions)
Line 140: Line 140:
<p> This first model is very interesting to understand which parameters govern the evolution of the living cell population and to show that conditions exist to stabilize it. But unfortunately this set of equation is insufficient account for the results of the experiments. </p>
<p> This first model is very interesting to understand which parameters govern the evolution of the living cell population and to show that conditions exist to stabilize it. But unfortunately this set of equation is insufficient account for the results of the experiments. </p>
 +
<br>
 +
<img src="https://static.igem.org/mediawiki/2013/7/76/Build_Exp1_OD.png">
 +
<img src="https://static.igem.org/mediawiki/2013/6/61/Build_Exp1_fluo.png">
Line 205: Line 208:
<p> The curves drawn from the model gives the right trend, observed in the experiments: the lag of the reaction, the peak of fluorescence short after light is switched on and then the swift decrease of fluorescence in the long term are qualitatively described. </p>
<p> The curves drawn from the model gives the right trend, observed in the experiments: the lag of the reaction, the peak of fluorescence short after light is switched on and then the swift decrease of fluorescence in the long term are qualitatively described. </p>
<br>
<br>
 +
 +
 +
<img src="https://static.igem.org/mediawiki/2013/4/41/Build_Exp2_OD.png">
 +
 +
 +
<img src="https://static.igem.org/mediawiki/2013/1/11/Build_Exp2_fluo.png">
 +
 +
<br>
<br>
<p>Nonetheless, it is impossible to get a good fit between the prediction of the model and the experiment. The maturation step alone does not explain why the production of KillerRed is so high two hours after the beginning of the illumination and the decrease of fluorescence is so rapid four hours after the illumination.</p>
<p>Nonetheless, it is impossible to get a good fit between the prediction of the model and the experiment. The maturation step alone does not explain why the production of KillerRed is so high two hours after the beginning of the illumination and the decrease of fluorescence is so rapid four hours after the illumination.</p>
Line 277: Line 288:
<p> With this model, we can now properly describe our data : </p>
<p> With this model, we can now properly describe our data : </p>
 +
<img src="https://static.igem.org/mediawiki/2013/e/e6/Build_Exp3_OD.png">
 +
<img src="https://static.igem.org/mediawiki/2013/c/c9/Build_Exp3_fluo.png">
</li>
</li>

Revision as of 05:17, 3 October 2013

Grenoble-EMSE-LSU, iGEM


Grenoble-EMSE-LSU, iGEM

Retrieved from "http://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Modelling/Building"