15/08/13

From 2013.igem.org

(Difference between revisions)
(Serial dilution of herring sperm DNA)
 
(3 intermediate revisions not shown)
Line 17: Line 17:
*100ul DNA and 900ul TE to make master mix
*100ul DNA and 900ul TE to make master mix
-
*5 independent samples
+
*5 independent samples 10ul each were taken from master mix
 +
**Each independent sample was diluted twice in 90ul of TE
 +
*20 dilution samples were then nanodropped to check dilution accuracy
 +
{|border=1
 +
|Sample nr||Concentration (ng/ul)||260/280||260/230
 +
|-
 +
|nr. 1/1||529.9||1.81||2.26
 +
|-
 +
|nr. 1/2||52.1||1.86||2.32
 +
|-
 +
|nr. 2/1||454.3||1.81||2.28
 +
|-
 +
|nr. 2/2||46||1.82||2.23
 +
|-
 +
|nr. 3/1||457.3||1.83||2.28
 +
|-
 +
|nr. 3/2||45.1||1.85||2.38
 +
|-
 +
|nr. 4/1||522.8||1.82||2.27
 +
|-
 +
|nr. 4/2||47.3||1.87||2.26
 +
|-
 +
|nr. 5/1||481.4||1.82||2.28
 +
|-
 +
|nr. 5/2||40.8||1.84||2.35
 +
|}
 +
 
 +
*Dilutions show accuracy
 +
*Master dilution is sonicated and every 30mins a 30ul sample is taken to dilute twice (10ul of DNA in 90ul of TE buffer)
 +
*6 30ul samples are taken
 +
*Samples are then run on a gel

Latest revision as of 13:29, 15 August 2013

Home Team Official Team Profile Project Parts Submitted to the Registry Modeling Notebook Safety Attributions


Serial dilution of herring sperm DNA

  • 100ul DNA and 900ul TE to make master mix
  • 5 independent samples 10ul each were taken from master mix
    • Each independent sample was diluted twice in 90ul of TE
  • 20 dilution samples were then nanodropped to check dilution accuracy
Sample nrConcentration (ng/ul)260/280260/230
nr. 1/1529.91.812.26
nr. 1/252.11.862.32
nr. 2/1454.31.812.28
nr. 2/2461.822.23
nr. 3/1457.31.832.28
nr. 3/245.11.852.38
nr. 4/1522.81.822.27
nr. 4/247.31.872.26
nr. 5/1481.41.822.28
nr. 5/240.81.842.35
  • Dilutions show accuracy
  • Master dilution is sonicated and every 30mins a 30ul sample is taken to dilute twice (10ul of DNA in 90ul of TE buffer)
  • 6 30ul samples are taken
  • Samples are then run on a gel