Team:Grenoble-EMSE-LSU/Project/Instrumentation
From 2013.igem.org
(3 intermediate revisions not shown) | |||
Line 18: | Line 18: | ||
<li id="titre"> | <li id="titre"> | ||
<h1>TalkE'coli - Our device</h1> | <h1>TalkE'coli - Our device</h1> | ||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
<h2 id="Overview">Overview of the device</h2> | <h2 id="Overview">Overview of the device</h2> | ||
<p>Our project aims to <strong>control the concentration of living bacteria in a culture</strong>. To do so, we designed <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Biology">a genetic network allowing light controlled cell growth</a>. In addition, we built a device in order to send and receive light signals from the bacterial culture. We have thus to create <strong>a means of communication from cell to machine and from machine to cell</strong>. For cell to machine communication, we chose to measure <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Biology">the red fluorescence of KillerRed</a>. The first function of our device is to excite and measure fluorescence intensity thanks to a light source, excitation/emission optics and a photodiode. In this way, our bacteria will be able to talk to our device. For machine to cell communication, we will use red light to activate <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Biology/KR"> light-inducible promoter</a> that triggers KillerRed production and white light to generate ROS thanks to KillerRed phototoxic activity. In our system, the rate of KillerRed production and the number of living cells will be controlled by the intensity of the red and white light beams. Therefore, a second function of our device is to generate controlled light intensities at different wavelengths. In this way, our device will be able to talk to our bacteria.</br></br></p> | <p>Our project aims to <strong>control the concentration of living bacteria in a culture</strong>. To do so, we designed <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Biology">a genetic network allowing light controlled cell growth</a>. In addition, we built a device in order to send and receive light signals from the bacterial culture. We have thus to create <strong>a means of communication from cell to machine and from machine to cell</strong>. For cell to machine communication, we chose to measure <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Biology">the red fluorescence of KillerRed</a>. The first function of our device is to excite and measure fluorescence intensity thanks to a light source, excitation/emission optics and a photodiode. In this way, our bacteria will be able to talk to our device. For machine to cell communication, we will use red light to activate <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Biology/KR"> light-inducible promoter</a> that triggers KillerRed production and white light to generate ROS thanks to KillerRed phototoxic activity. In our system, the rate of KillerRed production and the number of living cells will be controlled by the intensity of the red and white light beams. Therefore, a second function of our device is to generate controlled light intensities at different wavelengths. In this way, our device will be able to talk to our bacteria.</br></br></p> | ||
Line 36: | Line 28: | ||
<h2 id="Box">The Box</h2> | <h2 id="Box">The Box</h2> | ||
<p align="center"><object width="480" height="360"><param name="movie" value="//www.youtube.com/v/OY0-y8JZme0?version=3&hl=fr_FR"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="//www.youtube.com/v/OY0-y8JZme0?version=3&hl=fr_FR" type="application/x-shockwave-flash" width="480" height="360" allowscriptaccess="always" allowfullscreen="true"></embed></object></br></br></p> | <p align="center"><object width="480" height="360"><param name="movie" value="//www.youtube.com/v/OY0-y8JZme0?version=3&hl=fr_FR"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="//www.youtube.com/v/OY0-y8JZme0?version=3&hl=fr_FR" type="application/x-shockwave-flash" width="480" height="360" allowscriptaccess="always" allowfullscreen="true"></embed></object></br></br></p> | ||
- | <p>Our device is built in such a way that the user <strong>only</strong> needs to <strong>define the concentration of living cells</strong> he wants and put <strong>the Erlenmeyer with our engineered bacteria</strong>. From that moment on, the device works in <strong>standalone manner</strong>. It first measures <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Instrumentation/Fluo#Fluo">the initial red fluorescence</a> (<strong>the baseline</strong>). Then it induces the <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Biology#KR">KillerRed</a> protein using <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Biology/KR">the red-inducible promoter</a>. Every <strong>5 minutes</strong>, | + | <p>Our device is built in such a way that the user <strong>only</strong> needs to <strong>define the concentration of living cells</strong> he wants and put <strong>the Erlenmeyer with our engineered bacteria</strong>. From that moment on, the device works in <strong>standalone manner</strong>. It first measures <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Instrumentation/Fluo#Fluo">the initial red fluorescence</a> (<strong>the baseline</strong>). Then it induces the <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Biology#KR">KillerRed</a> protein using <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Biology/KR">the red-inducible promoter</a>. Every <strong>5 minutes</strong>, TalkE'Coli measures <strong>the red fluorescence level</strong> of the culture. Then the light is switched on and the fluorescence is further recorded. This info is used to <strong>build <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Modelling/Building">a model</a> of cell growth and KillerRed response to illumination</strong>. The computer then calculates the <strong>time profile</strong> of the white light intensity used to <strong>stabilize</strong> the living cell concentration. <strong>The main asset</strong> of the device is that it recalculates the model <strong>during the run and thus adjusts the light intensity more precisely</strong>. Finally, when the living cell population is <strong>stabilized at 10% of its target value</strong>, the computer sends a signal to the user to tell him the success of the procedure. |
+ | </br></br></p> | ||
<p>First, we will explain the choice of the different components, then the several experiments we did to find the most accurate parameters for each part of the device : <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Instrumentation/Fluo#Photodiode">the photodiode and Arduino</a>, <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Instrumentation/Fluo#Fluo">fluorescence measurement</a>, <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Instrumentation/Fluo#Electronic">the electronic circuit</a>, <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Instrumentation/Fluo#Servo">the servomotor</a>. All these elements were then integrated in <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Instrumentation/Fluo#Box">the box</a> that we designed and built.</p> | <p>First, we will explain the choice of the different components, then the several experiments we did to find the most accurate parameters for each part of the device : <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Instrumentation/Fluo#Photodiode">the photodiode and Arduino</a>, <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Instrumentation/Fluo#Fluo">fluorescence measurement</a>, <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Instrumentation/Fluo#Electronic">the electronic circuit</a>, <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Instrumentation/Fluo#Servo">the servomotor</a>. All these elements were then integrated in <a href="https://2013.igem.org/Team:Grenoble-EMSE-LSU/Project/Instrumentation/Fluo#Box">the box</a> that we designed and built.</p> | ||
</li> | </li> |
Latest revision as of 02:44, 5 October 2013