Team:DTU-Denmark/Notebook/26 June 2013
From 2013.igem.org
(→Main purposes today) |
(→Main purposes today) |
||
Line 16: | Line 16: | ||
A mastermix was made for both PCR with standard concentration [https://2013.igem.org/Team:DTU-Denmark/Methods/PCR-mastermix setup] and one additional volume for pipetting errors: | A mastermix was made for both PCR with standard concentration [https://2013.igem.org/Team:DTU-Denmark/Methods/PCR-mastermix setup] and one additional volume for pipetting errors: | ||
- | x7 mastermix for 16rxn | + | =====x7 mastermix for 16rxn===== |
*160uL HF buffer | *160uL HF buffer | ||
*16uL dNTP's 10mM | *16uL dNTP's 10mM | ||
Line 22: | Line 22: | ||
*440uL MQ | *440uL MQ | ||
- | PHUSION mastermix for 20rxn | + | =====PHUSION mastermix for 20rxn===== |
*200uL HF buffer | *200uL HF buffer | ||
*20uL dNTP's 10mM | *20uL dNTP's 10mM | ||
*10uL x7 polymerase | *10uL x7 polymerase | ||
*5500uL MQ | *5500uL MQ | ||
+ | |||
+ | The tubes were run on two programs simultaneously | ||
==Who was in the lab== | ==Who was in the lab== |
Revision as of 07:37, 27 June 2013
Contents |
208 lab
Main purposes today
helloworld-project
- 25 rxns including duplicates
- 34 rxna including duplicates with the following setup:
Tube 1-6 containing 5uL pZA21 plasmid template and 3uL of each primers for amplification of the backbone. Tube 7-10; 1uL g-Block from previous purification and 3uL of each Sec signal primers. Tube 11-14 containing same amount of g-Block and primers but now replaced with the TAT2 signal primers. Tube 15-18; 5uL GFP SF plasmid template and 3uL of each primers for GFP SF TAT. Tube 19-22; 5uL GFP SF plasmid template and 3uL of each primers for GFP SF Sec. Tube 23-26; 5uL RFP plasmid template and 3uL of each primer for RFP. Tube 27-30; 1uL g-Block purification and 3uL of each TAT3 primers. Tube 31-34; 0.5uL of the original g-Block and 3uL of each primers for amplifying the g-Block. All tube with less than 5uL template DNA was filled with MQ until final volume of 11uL(5+3+3).
First half of the samples where run on PCR with x7-polymerase and the second half where run with PHUSION-polymerase, with the exception of the g-Block where all reactions where run with PHUSION. This gives following setup: x7-poly in tube:
- 1-3, 7-8, 11-12, 15-16, 19-20, 23-24, 27-28
PHUSION in tube:
- 4-6, 9-10, 13-14, 17-18, 21-22, 25-26, 29-30, 31-34
A mastermix was made for both PCR with standard concentration setup and one additional volume for pipetting errors:
x7 mastermix for 16rxn
- 160uL HF buffer
- 16uL dNTP's 10mM
- 8uL x7 polymerase
- 440uL MQ
PHUSION mastermix for 20rxn
- 200uL HF buffer
- 20uL dNTP's 10mM
- 10uL x7 polymerase
- 5500uL MQ
The tubes were run on two programs simultaneously
Who was in the lab
Henrike, Jakob, Kristian
Procedure
PCR for 7 fragments: