Team:GeorgiaTech/RBS Primer

From 2013.igem.org

(Difference between revisions)
Line 78: Line 78:
Examples:
Examples:
-
[[File:96 Well 1.jpg|700px]]
+
[[File:12 well 1.jpg|700px]]
[[File:96 Well 2.jpg|700px]]
[[File:96 Well 2.jpg|700px]]
All bands beside the ladder are biobricks that have been amplified with the RBS primer and the reverse sequencing primer.
All bands beside the ladder are biobricks that have been amplified with the RBS primer and the reverse sequencing primer.

Revision as of 17:10, 27 September 2013

Contents

Purpose

The RBS primer is a standard primer that can be used for site directed mutagenesis in all linearized backbones available from the iGEM database.

Background

Most of the BioBrick parts requires a Ribosomal Binding Site to express the protein. This has proven problematic as the RBS is very small and hard to insert using 3A Assembly. We believe the creation of an oligo primer with this RBS may be easier to place the RBS in front of the protein that is needed to be expressed. An easy oligo primer that could be used in PCR extension and then placed into a vector backbone would save time and frustration as to whether the part had been inserted.

Design

The format of this primer needs the BioBrick formatted prefix with an additional strong Ribosomal binding site within it. The prefix of the standard BioBrick was analyzed and the primer was found to be able to be inserted after the XbaI site and still have the scar intact between the part and the RBS site.

RBS Primer.jpg

TGGAATTCGCGGCCGCTTCTAGAGAAAGAGGAGAAATACTAGATG

Daily Progress

The primer has been ordered and should be arriving soon.


July, 12 2013

The primer has arrived and several tests will be performed to determine if the primer is usable.

I have found an RFP BioBrick part that begins with ATG, which is needed for this primer to work, BBa_E1010. I will transform and purify another part to use as a positive control, BBa_E0430.

Through these I can set up the PCR reaction to test the addition of the RBS to the BioBrick part. The primer will be diluted to 5uM, 10 uM, and 20 uM. The BioBrick for the addition of the primer will be diluted to 0.5 ng/uL. The other primer that I will use is the complementary primer for the plasmid amplification, SB-prep-2Ea.

Edit: I have now switched to using the reverse primer for BioBrick Sequencing, BBa_G00101 (VR)

The PCR Protocol will be as follows:

  1. 90°C for 2 minutes
  2. 98°C for 30 seconds
  3. 48°C for 30 seconds
  4. 68° C for 5 minutes
  5. Repeat steps 2-4 for 32 cycles
  6. End with 68°C for 10 minutes

Cells will be transformed and then purified and sent off for sequencing.


The recipe is:

  • 5x reaction buffer - 10 µL
  • oligo1 (5, 10, 20 µM solution) - 7.5 µL
  • oligo2 (5, 10, or 20 µM solution) - 7.5 µL
  • dNTP mix (10mM each) - 1 µL
  • DMSO - 1 µL
  • H2O - 22.5 µL
  • Phusion DNA polymerase - 0.5 µL

Divide reaction in 2 tubes - negative control and reaction (~25 µL each); add 0.5 µL of DNA (0.1 ng) to the reaction

July 23, 2013

Using the 7.5 uL of the 5 uM oligo and the 363 BioBrick ASP, amplification was attempted again. This time with RFP. Results showed that RFP was amplified around the 800 bp mark, where it should be.

The amplicon was DpnI digested and PCR cleaned up with the Qiacube.

July 24, 2013

Attempted 2 ligations with RFP amplicon. 1 onto a Kanamycin backbone and the other with a pLac in front of it using 3A. These were plated on Kanamycin plates.

July 25, 2013

Growth was show on the plates, however, I decided not to do a colony PCR as the results from colony PCRs have been misleading lately.

Media solutions of 3 clones from each plate were made to be grown up overnight.

July 26, 2013

The media solutions were purified and ran a restriction digest. The results were promising although not definite. Will send off for sequencing.

July 30, 2013

Sequencing was returned. None of the clones had the RBS or any part for that matter. Strange though, some lost their XbaI site and did not have a PstI site.

July 31, 2013

Attempted the amplification again, this time with multiple different vectors that began with ATG. If the primer works, there should be bands around the respective differently length vectors. The vectors chosen were lacZa (234 bp), RFP(681 bp), and Antigen 43 (3000bp).

August 1, 2013

The next step was to gel purify each of the inserts. However, when the 0.6% gel was run, the wells made were misshapen, causing irregular bands to form. The purification was attempted regardless, but most likely this will need to be redone on new gels.


September 12, 2013

After extensive testing, many PCR reactions were run with the primer vast amount of BioBricks in unison to prove that it can amplify many BioBricks at once and be an effective tool.

Examples:

700px

700px

All bands beside the ladder are biobricks that have been amplified with the RBS primer and the reverse sequencing primer.