Team:DTU-Denmark/Notebook/28 August 2013

From 2013.igem.org

(Difference between revisions)
(Procedure)
(Procedure)
Line 65: Line 65:
* 4 ml from ''Nitrosomonas Europaea'' in 44 ml of ATCC media with 0.7 ml of ammonium solution
* 4 ml from ''Nitrosomonas Europaea'' in 44 ml of ATCC media with 0.7 ml of ammonium solution
   
   
 +
OD was measured OD=0.4017 and 0.3864 for the HAO mutant.  0.0822 and 0.0947. For ''Nitrosomonas Europaea'' was 0.0095 and 0.0084.
OD was measured OD=0.4017 and 0.3864 for the HAO mutant.  0.0822 and 0.0947. For ''Nitrosomonas Europaea'' was 0.0095 and 0.0084.

Revision as of 15:41, 28 September 2013

28 August 2013

Navigate to the Previous or the Next Entry

Contents

Lab 208


Main purpose


Who was in the lab


Henrike, Kristian, Julia

Procedure


A gradient PCR was made for pSB1C3 and pZA21::ara for Nir.

The master mix contains:

  • CG buffer,
  • X7 polymerase,
  • 2% of DMSO (1uL of 100%DMSO) per reaction
  • 1mM MgCl2 (1uL of 50mM MgCl2) per reaction
1 2
Template pSB1C3 pZA21::ara
Primers 57a + 57b 58a + 58b
Temperature range 58C-78C 50C-65C
Elongation time per cycle 1:30 min 2 min

Each reaction was run in one of the 12 different annealing temperatures within the range indicated in the table. We followed the standard PCR program.

Results


Conclusion



lab 115


Main purpose


Run Experiment 4 in two different samples aerobically in order to characterize the behavior of HAO transformants and the Nitrosomonas europaea strain.

Who was in the lab


Ariadni, Helen, Kashia

Procedure


Adjusting the temperature at 36 degrees and calibrating the probes as described in Calibration protocol.


Following the protocol Experiment 4

Growing:

  • two replicates of 4 ml from HAO overnight culture in 50 ml of DM minimal medium with NH4Cl and 25 ul of hydroxylamine solution
  • 4 ml from Nitrosomonas Europaea in 42 ml of ATCC media with 20 ul of hydroxylamine solution
  • 4 ml from Nitrosomonas Europaea in 44 ml of ATCC media with 0.7 ml of ammonium solution


OD was measured OD=0.4017 and 0.3864 for the HAO mutant. 0.0822 and 0.0947. For Nitrosomonas Europaea was 0.0095 and 0.0084.

Results


Colorimetric results

Ranges

  • Measuring range 5-150 mg/L NH4-N
  • Measuring range 0.02-1 mg/L NO2-N


Standard solutions

  • Ammonium - 66.6 mg/L (expected 39 mg/L)
  • Nitrite - 0.72 mg/L (expected 0.5 mg/L)


time (min)ammonium AMO1(mg/L) ammonium AMO2(mg/L) Ammonium E.coli(mg/L) nitrite E.coli ammonium abiotic (mg/L) nitrite abiotic(mg/L)
0 <5 <5 <5 <0.02 5 <0.02
13 <5 <5 5 <0.02 - -
19 <5 <5 5 <0.02 - -
spike 146 140 <5 <0.02 - -
35 158 244 258 <0.02 - -
41 169.5 171 178 <0.02 - -
52 226 280 250 <0.02 - -
64 232 254 124 <0.02 - -
90 238 272 246 <0.02 - -
10 hours 172 218 16 <0.02 154 <0.02

OD at the end of the experiment

OD=0.2083 and 0.2232 for the AMO mutants. For the E.coli culture the OD was 2.39 and 0.1173.The abiotic controls have OD=0.00144 and 0.0004.

Conclusion


Navigate to the Previous or the Next Entry