Team:DTU-Denmark/Notebook/27 June 2013

From 2013.igem.org

(Difference between revisions)
(Conclusion from today)
Line 1: Line 1:
 +
{{:Team:DTU-Denmark/Templates/StartPage|05 June 2013}}
 +
=208 lab=
=208 lab=
-
+
<hr/>
== Main purposes today ==
== Main purposes today ==
 +
<hr/>
Run gels to verify [https://2013.igem.org/Team:DTU-Denmark/Notebook/26_June_2013 yesterdays] PCR-prodcuts. Make new PCR to amplify the signal peptides and the backbone.
Run gels to verify [https://2013.igem.org/Team:DTU-Denmark/Notebook/26_June_2013 yesterdays] PCR-prodcuts. Make new PCR to amplify the signal peptides and the backbone.
==who were in the lab==
==who were in the lab==
 +
<hr/>
Gosia, Henrike, Kristian
Gosia, Henrike, Kristian
==Procedure==
==Procedure==
 +
<hr/>
Signal peptides on 4% gels 80V for 45 min. All other PCR-products on a 1% gel 100V for 45 min.  
Signal peptides on 4% gels 80V for 45 min. All other PCR-products on a 1% gel 100V for 45 min.  
Two new PCRs with ramp from 70°C &rarr; 60°C and 60°C &rarr; 50°C. Sec signal peptide on 70°C &rarr; 60°C and TAT signal peptide with new primer set 2 and 3 respectively on program 60°C &rarr; 50°C. Also backbone, GFPs and RFP where on these programs but non worked.
Two new PCRs with ramp from 70°C &rarr; 60°C and 60°C &rarr; 50°C. Sec signal peptide on 70°C &rarr; 60°C and TAT signal peptide with new primer set 2 and 3 respectively on program 60°C &rarr; 50°C. Also backbone, GFPs and RFP where on these programs but non worked.
-
[[File:27.06.13_Sec_and_TAT_signalP.jpg|thumb|left|The gel of the successful PCR-amp. of the two signal peptides. Going from left to right; 100bp ladder, Sec signalP, Sec signalP, TAT with TAT2 primers, TAT with TAT2 primers, TAT with TAT3 primers, TAT with TAT3 primers. Note that TAT with TAT2 primers are a little longer than TAT with TAT3 primers because the insertion of 2 additional amino acids.]]
 
Purification af the signal peptides where done with Illustra MicroSpin G-50 with filters all sequences under 50 bp.  
Purification af the signal peptides where done with Illustra MicroSpin G-50 with filters all sequences under 50 bp.  
Gel purification of weak band of the GFP SF.
Gel purification of weak band of the GFP SF.
-
[[File:27.06.13_gel_puri_GFP_Sec_and_GFP_TAT.jpg|thumb|left|The gel from where we purified GFP SF Sec and GFP SF TAT]]
+
 
 +
[[File:27.06.13_gel_puri_GFP_Sec_and_GFP_TAT.jpg|thumb|270px|left|The gel from where we purified GFP SF Sec and GFP SF TAT]]
 +
 
 +
[[File:27.06.13_Sec_and_TAT_signalP.jpg|thumb|270px|left|The gel of the successful PCR-amp. of the two signal peptides. Going from left to right; 100bp ladder, Sec signalP, Sec signalP, TAT with TAT2 primers, TAT with TAT2 primers, TAT with TAT3 primers, TAT with TAT3 primers. Note that TAT with TAT2 primers are a little longer than TAT with TAT3 primers because the insertion of 2 additional amino acids.]]
== Conclusion from today ==
== Conclusion from today ==
 +
<hr/>
We have all PCR-fragments except the backbone.
We have all PCR-fragments except the backbone.
Sec signal peptide can be amplified successfully with a [[Team:DTU-Denmark/Methods/PCR-ramp|ramp]] 70°C &rarr; 60°C and TAT signal peptide with both TAT2 og and TAT3 primers can be amplified with ramp from 60°C &rarr; 50°C. Both with 0.1°C/s.
Sec signal peptide can be amplified successfully with a [[Team:DTU-Denmark/Methods/PCR-ramp|ramp]] 70°C &rarr; 60°C and TAT signal peptide with both TAT2 og and TAT3 primers can be amplified with ramp from 60°C &rarr; 50°C. Both with 0.1°C/s.
 +
 +
 +
 +
{{:Team:DTU-Denmark/Templates/EndPage}}

Revision as of 07:55, 12 July 2013

05 June 2013

Contents

208 lab


Main purposes today


Run gels to verify yesterdays PCR-prodcuts. Make new PCR to amplify the signal peptides and the backbone.

who were in the lab


Gosia, Henrike, Kristian

Procedure


Signal peptides on 4% gels 80V for 45 min. All other PCR-products on a 1% gel 100V for 45 min. Two new PCRs with ramp from 70°C → 60°C and 60°C → 50°C. Sec signal peptide on 70°C → 60°C and TAT signal peptide with new primer set 2 and 3 respectively on program 60°C → 50°C. Also backbone, GFPs and RFP where on these programs but non worked.

Purification af the signal peptides where done with Illustra MicroSpin G-50 with filters all sequences under 50 bp. Gel purification of weak band of the GFP SF.

The gel from where we purified GFP SF Sec and GFP SF TAT
The gel of the successful PCR-amp. of the two signal peptides. Going from left to right; 100bp ladder, Sec signalP, Sec signalP, TAT with TAT2 primers, TAT with TAT2 primers, TAT with TAT3 primers, TAT with TAT3 primers. Note that TAT with TAT2 primers are a little longer than TAT with TAT3 primers because the insertion of 2 additional amino acids.


Conclusion from today


We have all PCR-fragments except the backbone.

Sec signal peptide can be amplified successfully with a ramp 70°C → 60°C and TAT signal peptide with both TAT2 og and TAT3 primers can be amplified with ramp from 60°C → 50°C. Both with 0.1°C/s.