Team:UCSF/Modeling
From 2013.igem.org
Line 85: | Line 85: | ||
- | <div id="description" align="justify" style = "width:950px; height: | + | <div id="description" align="justify" style = "width:950px; height:80px"> |
<font face="calibri" size = "4"> | <font face="calibri" size = "4"> | ||
- | <br><b><FONT COLOR="#008000"> | + | <br><b><FONT COLOR="#008000">EQUATIONS</FONT COLOR="#008000"></b> <p> |
- | </div> | + | |
+ | |||
+ | |||
+ | Given these assumptions we have the following equations for the system: <br> | ||
+ | Fluorescent proteins: <br></div> | ||
+ | |||
<div id="photos"> | <div id="photos"> | ||
- | <center><img style="height: | + | <center><img style="height:40px"; padding:0;" |
- | src="https://static.igem.org/mediawiki/2013/ | + | src="https://static.igem.org/mediawiki/2013/7/70/UCSF_Modeling_Image008.png"> </center></div> |
+ | <div id="photos"> | ||
+ | <center><img style="height:40px"; padding:0;" | ||
+ | src="https://static.igem.org/mediawiki/2013/1/19/UCSF_Modeling_Image010.png"> </center></div> | ||
<div id="description" align="justify" style = "width:950px; height:40px"> | <div id="description" align="justify" style = "width:950px; height:40px"> |
Revision as of 06:46, 28 October 2013
The primary goal of the modeling portion for the synthetic circuit project is to create a model that will help us figure out the right parameters, given our assumptions, which will generate the desired result, a Decision Making Circuit (Figure 1). In other words, we want a circuit that exhibits behavior A given a certain input and behavior B when the input is changed. A computer model can help us rapidly prototype by providing an environment where we can test out different promoters and repression strengths in the computer before we spend the time building and testing strains in the lab. The circuit is designed to produce different outputs according to different levels of inducer by utilizing the CRISPRi system. In lower concentrations of inducer, the guide RNA (gRNA) will be made to repress RFP. In higher concentrations of inducer, another gRNA will be made to repress GFP. The circuit should express GFP at lower inducer concentrations and RFP at high inducer concentrations, as shown in Figure 1 below.
ASSUMPTIONS: While creating the model for our system, we made five assumptions in order to simplify some of the aspects of the model:
1) protein degradation is linear;
2) protein production is based on a hill function and also depends on inducer concentration;
3) repression is governed by a hill function and depends on the concentration of dCas9 and gRNA complex;
4) that the binding and unbinding of dCas9 and gRNA complex happens much faster than the production/degradation of gRNA and fluorescent proteins (the complex is at Quasi Steady State).
5) everything diffuses quickly throughout the cell so that our differential equations depends on the concentration at any given time.
EQUATIONS
Given these assumptions we have the following equations for the system:
Fluorescent proteins:
EQUATIONS:
For fluorescent proteins
Protein Production Equations Depend on Inducer & Repressor Complex:
These next two equations describe the binding and unbinding of the gRNA and dCas9 complex:
gRNA(repressor)/dCas9 Complex:
gRNAs:
Amount of dCas9 Available in the System:
The equations for the gRNAs depend on the amount of the gRNAs that is produced, the degradation rate, and also the rate at which the gRNA complexes with dCas9.
The available amount of dCas9 depends on the amount of the two different complexes and also the amount of free dCas9.
This model has many parameters, so in order for it to be more useful, we need to reduce the number of parameters that are undetermined. To accomplish this, we gathered some values from literature and also did experiments to find other parameters.
How does the system change when the hill coefficient is manipulated? In this first plot, the hill coefficients for both the low and the high function are the same number: 2.551. This number is the one we determined from our experimental data.
nL = 2.551
nH = 2.551
nL = 2.551
nH = 1.551
How does the model look with our actual “low” and “high” promoters?
If the only change in the low and high functions (FH and FL) is the K values (which determine the sensitivity of the promoters), then we don’t get our desired behavior. However, there are other parameters that might give us the desired behavior for the low and high promoters.