Team:Paris Bettencourt/Notebook/Phage Sensor/Thursday 3rd October.html

From 2013.igem.org

Revision as of 10:59, 25 October 2013 by Annelöchner (Talk | contribs)

Detect

Wedsnesday 3rd October

Killing assay to test specifity of CRISPR Cas

Electrocompetent cells (delta PyrF, parental, NEB)
1) Start Culture
2) When the cells reach an OD600 of 0.2.
3) Harvest the cells.
When the cells reach an OD600 of between 0.6 and 0.8 (OD: 0,683)
Centrifuge at 4 °C for 10 min at 4000 rpm.
4) Wash and combine the cells.
Remove the supernatant.
Resuspend the cells in 25 ml of ice cold water
5) Wash the cells 2 more times.
Centrifuge at 4 °C for 10 min at 4000 rpm.
Resuspend in 50 ml of ice cold water.
Repeat.
6) Wash and concentrate the cells for electroporation.
Centrifuge at 4 °C for 10 min at 4000 rpm.
Resuspend in 1-2 ml of ice cold water.
We will use 200 ul of washed cells per transformation.

Transformation
Cotransform into parental/keio delta pyRF: pS006* (Cas9 in Amp BB) + pS004'(gRNA in Chl BB).
1) Prepare BD tubes with a pipette filled with LB at the interior of each tube (pipette supplied with the electroporation cuvette)
2) Test the purity of the electrocompetent cells.
Add 200 ul of washed cells to a cuvette.
3) Mix the cells and DNA in a cuvette.
200 ul of washed cells with 200 ng of PCR product.
Keep the cuvette on ice until just before the electroporation.
4) Preload a pipette with 1 ml of LB.
5) Pulse the cuvette with voltage.
Dry the electrodes with a kimwipe prior to loading.
Use the EC2 setting.
6) Listen for arcing.
A cracking sound means all the cells are dead.
Note the time constant: 5 is good, 5.8 is great.
7) Immediately recover the cells.
Add the 1 ml of preloaded LB and pipet up and down to mix.
Collect 1 ml of cells, some volume is lost in the cuvette.
8) Incubate 1/2 h at 37 °C with shaking.
9) Plate 10/200 ul of recovered cells on selective plates.
Use antibiotic appropriate to the part being integrated.
Let the other 900 ul rest overnight at room temperature.
10) Concentrate and plate the remaining cells
Spin down quickly and resuspend in 100 ul LB before plating.
Transformed cells should be incubated at 37 °C.
Colonies should appear 24-48 h after plating.


Plating of 10/100ul on
1. Amp plates -> selection for only Cas9
2. Chl plates -> selection for only gRNA
3. Amp/Chl plates -> selection for theoretically functional system