Team:Washington/96WellPlateAssay

From 2013.igem.org

(Difference between revisions)
 
(7 intermediate revisions not shown)
Line 1: Line 1:
{{:Team:Washington/WA_Template}}
{{:Team:Washington/WA_Template}}
-
 
<html>
<html>
-
 
+
<blockquote>
<header>
<header>
-
<b><u>96 Well Plate Assay</u></b>
+
<b><u>96-Well Plate Assay</u></b>
</header>
</header>
<body>
<body>
 +
Obtain <a href = "http://www.fishersci.com/ecomm/servlet/itemdetail?storeId=10652&langId=-1&catalogId=-1&productId=3349439&distype=0&fromSearch=0">96-Well Plate</a>.</br>
1. Pipette 260 ul of the overnight culture prepared according to the <a href = "https://2013.igem.org/Team:Washington/GeneralProtocol">general protocol</a> to each well being tested and cover with a breathable plate seal.</br>
1. Pipette 260 ul of the overnight culture prepared according to the <a href = "https://2013.igem.org/Team:Washington/GeneralProtocol">general protocol</a> to each well being tested and cover with a breathable plate seal.</br>
-
2. Start the E. colight app and select the appropriate conditions.</br>
+
2. <a href = "https://2013.igem.org/Team:Washington/appsetup">Set the E. colight app</a> with the appropriate conditions.</br>
3. Orient the 96-well plate on the tablet such that the wells line up with the appropriate light source on the tablet and secure with tape.</br>
3. Orient the 96-well plate on the tablet such that the wells line up with the appropriate light source on the tablet and secure with tape.</br>
-
4. Incubate tablet and 96-well plate on an orbital shaker (RPM?) for 16 hours at 37C.</br>
+
4. Incubate tablet and 96-well plate on an orbital shaker at 240 RPM for 16 hours at 37C.</br>
5. Follow the <a href = "https://2013.igem.org/Team:Washington/FluorescentAnalysisProtocol">Fluorescent Analysis Protocol</a>.</br>
5. Follow the <a href = "https://2013.igem.org/Team:Washington/FluorescentAnalysisProtocol">Fluorescent Analysis Protocol</a>.</br>
-
 
+
<br>
</body>
</body>
</html>
</html>

Latest revision as of 22:27, 27 September 2013


96-Well Plate Assay
Obtain 96-Well Plate.
1. Pipette 260 ul of the overnight culture prepared according to the general protocol to each well being tested and cover with a breathable plate seal.
2. Set the E. colight app with the appropriate conditions.
3. Orient the 96-well plate on the tablet such that the wells line up with the appropriate light source on the tablet and secure with tape.
4. Incubate tablet and 96-well plate on an orbital shaker at 240 RPM for 16 hours at 37C.
5. Follow the Fluorescent Analysis Protocol.