Team:DTU-Denmark/Notebook/17 September 2013
From 2013.igem.org
(3 intermediate revisions not shown) | |||
Line 9: | Line 9: | ||
==Who was in the lab== | ==Who was in the lab== | ||
- | Helen, | + | Helen, Kasia, Ariadni |
- | + | ||
==Procedure== | ==Procedure== | ||
- | + | ||
+ | Following the protocol [[Team:DTU-Denmark/Methods/Bioreactor|Bioreactor]]. | ||
==Results== | ==Results== | ||
Line 38: | Line 38: | ||
| 1.65 mg/L | | 1.65 mg/L | ||
|} | |} | ||
+ | |||
+ | At the end of the experiment the OD measurements were: | ||
+ | |||
+ | {| class="wikitable" style="text-align: right" | ||
+ | ! OD(end)!! sample A!! sample B!! sample C | ||
+ | |- | ||
+ | | -|| 0.0255 || 0.1590 || 0.0801 | ||
+ | |- | ||
+ | |} | ||
+ | |||
===Colorimetric results=== | ===Colorimetric results=== | ||
Line 54: | Line 64: | ||
|- | |- | ||
|} | |} | ||
- | |||
== Conclusion == | == Conclusion == |
Latest revision as of 11:00, 4 October 2013
17 September 2013
Contents |
Lab 223
Main purpose
The purpose of this experiment is to determine the long term characteristics of the growth of our Nir transformant anerobically. Specifically, we measure nitrous oxide production over a period of 10 hours.
Who was in the lab
Helen, Kasia, Ariadni
Procedure
Following the protocol Bioreactor.
Results
Nitrous Oxide measured in the bioreactor at the beginning and end of the experiment.
Time | Replicate 1 | Replicate 2 | Replicate 3 | Control: Distilled Water |
---|---|---|---|---|
14:00 | 1.84 mg/L | 1.64 mg/L | 1.60 mg/L | N/A |
22:00 | 1.43 mg/L | 1.44 mg/L | 1.50 mg/L | 1.65 mg/L |
At the end of the experiment the OD measurements were:
OD(end) | sample A | sample B | sample C |
---|---|---|---|
- | 0.0255 | 0.1590 | 0.0801 |
Colorimetric results
Ranges
- Measuring range 5-150 mg/L NH4-N
- Measuring range 0.02-1 mg/L NO2-N
salt (mg/L) | sample A/start | sample A/end | sample B/start | sample B/end | sample C/start | sample C/end |
---|---|---|---|---|---|---|
ammonium | 18 | 18 | 16 | 6 | 18 | 14 |
nitrite | 0.93 | 0.91 | 0.92 | 1.72 | 0.9 | 0.9 |
Conclusion
There were several sources of error in this experiment. Most importantly, the experiment became aerobic in each chamber at 12:00, and the lab technician began sparging the reactors.
Navigate to the Previous or the Next Entry