Team:Braunschweig/Safety
From 2013.igem.org
Line 24: | Line 24: | ||
dl.imgRight {float: right; margin:10px 0px 10px 10px;} | dl.imgRight {float: right; margin:10px 0px 10px 10px;} | ||
dl.imgRight dd {margin:0; font-size:90%;} | dl.imgRight dd {margin:0; font-size:90%;} | ||
+ | |||
+ | a:link { text-decoration:none; color:#be1e3c; } | ||
+ | a:visited { text-decoration:none; color:#be1e3c; } | ||
+ | a:hover { text-decoration:none;} | ||
+ | a:active { text-decoration:none;} | ||
+ | a:focus { text-decoration:none;} | ||
.table {background:#11111 none repeat scroll 0 0; border:1px solid #AAAAAA; border-collapse:collapse; empty-cells:show; margin: 0 auto; } | .table {background:#11111 none repeat scroll 0 0; border:1px solid #AAAAAA; border-collapse:collapse; empty-cells:show; margin: 0 auto; } | ||
Line 34: | Line 40: | ||
<h1>Safety</h1></p> | <h1>Safety</h1></p> | ||
<img alt="linie rot 8pix hoch" src="https://static.igem.org/mediawiki/2013/0/07/Team_Braunschweig_Red_line.jpg" width="850" height="1" /> | <img alt="linie rot 8pix hoch" src="https://static.igem.org/mediawiki/2013/0/07/Team_Braunschweig_Red_line.jpg" width="850" height="1" /> | ||
- | <p><br>View our safety form <a href="https://static.igem.org/mediawiki/2013/9/91/Safety_Form_Braunschweig.pdf">here</a>. Safety forms were approved on September 29, 2013 by the iGEM Safety Committee.</p> | + | <p><br>View our safety form <b><a href="https://static.igem.org/mediawiki/2013/9/91/Safety_Form_Braunschweig.pdf">here</a></b>. Safety forms were approved on September 29, 2013 by the iGEM Safety Committee.</p> |
<img alt="grey line" src="https://static.igem.org/mediawiki/2013/4/4c/Braunschweig_grey_line.png" width="850" height="1" vspace="20"/> | <img alt="grey line" src="https://static.igem.org/mediawiki/2013/4/4c/Braunschweig_grey_line.png" width="850" height="1" vspace="20"/> |
Revision as of 14:17, 4 October 2013
Safety
View our safety form here. Safety forms were approved on September 29, 2013 by the iGEM Safety Committee.
Project Safety Concerns
While designing our project biosafety was a very important topic for us. Thus, our project consists of regulation of bacterial growth or even better regulation of bacterial growth by themselves depending on each other.
The two main parts we constructed contain an inducible Quorum Sensing dependent antibiotic resistance. The survivability of the bacteria is coupled to the expression of the antibiotic resistance gene which will only be induced when the other strain is present in the same culture broth or if synthetic autoinducer is added. If one strain is eliminated, the whole bacterial consortium dies; hence, we deemed that no other biological safety mechanisms are necessary yet.
For the future the regulation by an auxotrophic chassis is planned instead of the regulation by antibiotic resistances. Therefore the use of antibiotics and the respective negative implications of our project will be avoided.
Laboratory concerns
Guiding principle: Avoid hazardous chemicals, biological material and situations if possible!Main risks at the laboratory
To enable sterile work some ethanol was used to clean working space, with the advice that ethanol is easy flammable and only should just be used in small areas.
For our cultivations we had to add antibiotics to our media, which were handled with care because large amounts of them can cause harmful effects to health and could lead to resistances.
The major hazard during our lab work was the regular use of UV light and ethidium bromide, which is a DNA intercalating agent and can therefore cause cancer. Both had to be used for the visualization of gel electrophoresis.
Used organisms
The iGEM Team Braunschweig 2013 worked exclusively with non-pathogenic strains of E. coli, which means working with the lowest possible risk level.
Strain | Risk group | Risk to humans |
---|---|---|
E. coli XL1 Blue MRF' | 1 | No human pathogen, but may cause irritation to skin, eyes, and respiratory tract and may affect kidneys. |
E. coli Top10F' | 1 | No human pathogen, but may cause irritation to skin, eyes, and respiratory tract and may affect kidneys. |
E. coli JM109 | 1 | No human pathogen, but may cause irritation to skin, eyes, and respiratory tract and may affect kidneys. |
Safety equipment
To create a safe working environment, the provided lab space was equipped with safety showers, eye shower, fire-extinguishers and a fire blanket. Furthermore lab coats, gloves and safety goggles for all team members were available at any time. For protection against carcinogenic substances like ethidium bromide a special labeled area in the lab was used.
Equipment which was in contact with biological material and could not be reused was disposed in biohazard waste and autoclaved.
Personal safety
The iGEM Team Braunschweig 2013 focused a lot on self depending safety. In order to achieve that every team member had to attend in a special safety information training regarding safe handling of equipment, chemicals and biological material as well as general safety advice before starting any wet lab work. All team members got a tour and additional supervision in the lab and were only working in groups of at least two. Furthermore the lab work was coordinated by two team members who supervised the others when using new equipment or technique. During lab work the team members avoided hazardous chemicals whenever possible. In case hazardous chemicals could not be avoided appropriate safety measurements were taken.