Team:NCTU Formosa/results

From 2013.igem.org

(Difference between revisions)
(37 degrees Celsius RBS)
(37 degrees Celsius RBS)
Line 26: Line 26:
===37 degrees Celsius RBS===
===37 degrees Celsius RBS===
-
<p>Using Pcons+37°C RBS+mGFP+J61048, we tested the 37°C RBS function in different temperature.</p>
+
<p>Using biobrick, Pcons+37°C RBS+mGFP+J61048, we tested the function of the 37°C RBS under different temperatures.</p>
-
[[File:NCTU_37RBS_result.png|center|600px|Fig 3. 37°C RBS efficiency in different temperature.]]
+
[[File:NCTU_37RBS_result.png|center|600px|Fig 3. 37°C RBS efficiency under different temperatures.]]
-
<span class="undetermined">(undetermined)</span>
+
<span class="undetermined">As shown on Fig 3. the expression of mGFP under 37°C and 42°C reached a higher OD value in less time than the expression below 37°C. This demonstrates the fact that 37°C RBS functions more efficiently above or at 37°C. On the other hand, the fact that 37°C RBS leads to moderate expression even under 37°C degree might be a problem, since then we cannot make sure that only single gene is expressed under 37°C.</span>
</div></div>
</div></div>

Revision as of 09:16, 21 September 2013

Results

The current progress of our project, including detailed information of the experimental data and the overall evaluation of the practicability of this project.

Change the font size right here

Contents

RBS efficiency

We used the following biobrick to test the efficiency of different ribosome binding sites:

  1. Pcons+BBa_B0034+mRFP+Ter
  2. Pcons+[http://parts.igem.org/wiki/index.php?title=Part:BBa_K1017202 BBa_K1017202]+mRFP+Ter
  3. Pcons+BBa_B0030+mRFP+Ter
  4. Pcons+BBa_B0032+mRFP+Ter
  5. control:pet40

The control is pet40 and the reporter gene is mRFP, Figure 1 and Figure 2 show the difference of color.

(undetermined)

Fig 1. From left to right, the ribosome biding site respectively is: B0032, Target 1, B0030, B0034, control.
Fig 2. From left to right, the ribosome biding site respectively is: B0034, Target 1, B0030, B0032, control.

37 degrees Celsius RBS

Using biobrick, Pcons+37°C RBS+mGFP+J61048, we tested the function of the 37°C RBS under different temperatures.

Fig 3. 37°C RBS efficiency under different temperatures.

As shown on Fig 3. the expression of mGFP under 37°C and 42°C reached a higher OD value in less time than the expression below 37°C. This demonstrates the fact that 37°C RBS functions more efficiently above or at 37°C. On the other hand, the fact that 37°C RBS leads to moderate expression even under 37°C degree might be a problem, since then we cannot make sure that only single gene is expressed under 37°C.