Team:Peking/DataPage/Parts

From 2013.igem.org

(Difference between revisions)
Line 262: Line 262:
     <div id="ModelOverviewContainer">
     <div id="ModelOverviewContainer">
           <img id="ModelOverviewBackground" src="https://static.igem.org/mediawiki/2013/1/15/Peking2013_model_overview.jpg" />
           <img id="ModelOverviewBackground" src="https://static.igem.org/mediawiki/2013/1/15/Peking2013_model_overview.jpg" />
-
           <h1 id="ModelOverviewTitle">Data Page</h1>
+
           <h1 id="ModelOverviewTitle">Parts</h1>
           <h1 id="MoedlOverviewIntroduction">Introduction</h1>
           <h1 id="MoedlOverviewIntroduction">Introduction</h1>
           <p id="ModelOverviewContent">A regular reporter (for example, fluorescent proteins or pigment) can only detect a narrow range of concentration of input signals, (Figure 1) because they mainly possess a Hill-function type dose-response curve. The linear proportion of such a dose-response curve is relatively narrow,causing it sensitive to only a narrow range of input intensity. Thus the regular reporters are not proper devices for quantitative measurement. In order to design a quantitative, economical and convenient aromatics detector, we decided to build a band pass filter.<br/>
           <p id="ModelOverviewContent">A regular reporter (for example, fluorescent proteins or pigment) can only detect a narrow range of concentration of input signals, (Figure 1) because they mainly possess a Hill-function type dose-response curve. The linear proportion of such a dose-response curve is relatively narrow,causing it sensitive to only a narrow range of input intensity. Thus the regular reporters are not proper devices for quantitative measurement. In order to design a quantitative, economical and convenient aromatics detector, we decided to build a band pass filter.<br/>

Revision as of 11:43, 25 September 2013

Parts

Introduction

A regular reporter (for example, fluorescent proteins or pigment) can only detect a narrow range of concentration of input signals, (Figure 1) because they mainly possess a Hill-function type dose-response curve. The linear proportion of such a dose-response curve is relatively narrow,causing it sensitive to only a narrow range of input intensity. Thus the regular reporters are not proper devices for quantitative measurement. In order to design a quantitative, economical and convenient aromatics detector, we decided to build a band pass filter.

A regular reporter (for example, fluorescent proteins or pigment) can only detect a narrow range of concentration of input signals, (Figure 1) because they mainly possess a Hill-function type dose-response curve. The linear proportion of such a dose-response curve is relatively narrow,causing it sensitive to only a narrow range of input intensity. Thus the regular reporters are not proper devices for quantitative measurement. In order to design a quantitative, economical and convenient aromatics detector, we decided to build a band pass filter.