Team:UC Davis/Database/Standards
From 2013.igem.org
Line 68: | Line 68: | ||
<p> | <p> | ||
Constitutive promoters have the following additional requirements: <br> | Constitutive promoters have the following additional requirements: <br> | ||
- | + | <ol> | |
- | + | <li>Three wells must contain BBa_J23101 and a reporter. It should be analogous to your constitutive promoter of interest. This is to enable reporting in relative promoter units.</li> | |
- | + | <li>Three wells must contain just the media that you are using. In the parts name section, list this as "media_control".</li> | |
+ | <li>Three wells must contain the strain that you are using. In the parts name section, list this as "strain_control". | ||
+ | </li> | ||
+ | </ol> | ||
</p> | </p> | ||
<br> | <br> | ||
<h3>Inducible Promoters</h3> | <h3>Inducible Promoters</h3> | ||
<p> | <p> | ||
- | Inducible promoters have the <b>similar requirements as constitutive promoters, but</b> with two additional requirements: < | + | Inducible promoters have the <b>similar requirements as constitutive promoters, but</b> with two additional requirements: |
- | + | <ol> | |
- | + | <li>If applicable, three additional wells must contain the wild-type promoter and a reporter gene. The promoter of interest should be have an identical reporter gene attached. This is required because comparing the output of a constitutive promoter, BBa_J23101, to an inducible promoter is unfit in some applications. </li> | |
+ | <li>Have data over the entire range of fluorescence output by varying the inducer concentration from zero to saturation.</li> | ||
+ | </ol> | ||
</p> | </p> | ||
Revision as of 02:04, 28 September 2013
Standards in the Depot
Although there have been differing methods of characterizing Biobricks, the vast majority of characterizations use the measurement of fluorescence and cell density in a microplate reader. The standards can accommodate some other types of characterizations, but are best suited to report data as described.
Additionally, The Depot defines an uploadable experiment as: empirical measurements of a response from a single part type in the same construct that are affected by the same set of user-controlled variables.
All Part Types
1. The raw data file (.txt, .csv, .xls, .xlx) from the output of your machine. An example is shown here. | |
2. Standardized data file (csv) that reports your plate layout in the linked tabular format that is partly shown here. | |
3. Standardized data file (csv), that reports your fluorescence and cell density measurements in the linked tabular format that is partly shown here. | |
4. The metadata file (csv) that reports information on your experiment's conditions and settings in the linked tabular format that is fully shown here. | |
The well-IDs follow the following naming system, where the columns are numbered and the rows are capitalized letters. |
The following standards for specific part types inherit the requirements above in addition to their further requirements.
Constitutive Promoters
Constitutive promoters have the following additional requirements:
- Three wells must contain BBa_J23101 and a reporter. It should be analogous to your constitutive promoter of interest. This is to enable reporting in relative promoter units.
- Three wells must contain just the media that you are using. In the parts name section, list this as "media_control".
- Three wells must contain the strain that you are using. In the parts name section, list this as "strain_control".
Inducible Promoters
Inducible promoters have the similar requirements as constitutive promoters, but with two additional requirements:
- If applicable, three additional wells must contain the wild-type promoter and a reporter gene. The promoter of interest should be have an identical reporter gene attached. This is required because comparing the output of a constitutive promoter, BBa_J23101, to an inducible promoter is unfit in some applications.
- Have data over the entire range of fluorescence output by varying the inducer concentration from zero to saturation.
Visit the Depot |
Data StandardsSee the Depot's standards and data requirements so you can share your data as well. |
Initial PopulationSee how we initially populated the Depot. |
The DepotCheck out the motivations behind the Depot. |