Team:UC Davis/Database/Standards
From 2013.igem.org
(Difference between revisions)
(6 intermediate revisions not shown) | |||
Line 5: | Line 5: | ||
.black td{vertical-align:top; | .black td{vertical-align:top; | ||
text-align:justify;} | text-align:justify;} | ||
+ | #randcss5{clear:both;} | ||
</style> | </style> | ||
</head> | </head> | ||
Line 10: | Line 11: | ||
<div> | <div> | ||
- | <a href="http://dilbert.cs.ucdavis.edu/Depot/"><img src="https://static.igem.org/mediawiki/2013/ | + | <a href="http://dilbert.cs.ucdavis.edu/Depot/"><img src="https://static.igem.org/mediawiki/2013/3/30/Depotbanner_UCDavis_mod.jpg" class="banner" width=967px height=226/></a> |
</div> | </div> | ||
Line 18: | Line 19: | ||
<tr> | <tr> | ||
<td> | <td> | ||
- | <a href="http://dilbert.cs.ucdavis.edu/Depot/"><img src="https://static.igem.org/mediawiki/2013/4/4e/ | + | <a href="http://dilbert.cs.ucdavis.edu/Depot/"><img src="https://static.igem.org/mediawiki/2013/4/4e/Visitdepot_UCDavis.jpg" class="blur"></a> |
- | + | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 29: | Line 29: | ||
<p> | <p> | ||
Although there have been differing methods of characterizing Biobricks, the vast majority of characterizations use the measurement of fluorescence and cell density in a microplate reader. The standards can accommodate some other types of characterizations, but are best suited to report data as described. | Although there have been differing methods of characterizing Biobricks, the vast majority of characterizations use the measurement of fluorescence and cell density in a microplate reader. The standards can accommodate some other types of characterizations, but are best suited to report data as described. | ||
- | <br> | + | <br><br> |
Additionally, The Depot defines an uploadable experiment as: empirical measurements of a response from a single part type in the same construct that are affected by the same set of user-controlled variables. | Additionally, The Depot defines an uploadable experiment as: empirical measurements of a response from a single part type in the same construct that are affected by the same set of user-controlled variables. | ||
</p> | </p> | ||
+ | <br> | ||
- | |||
<p> | <p> | ||
<table class="black"> | <table class="black"> | ||
- | + | Uploading to The Depot requires the following: | |
<tr> | <tr> | ||
<td><img src="https://static.igem.org/mediawiki/2013/6/66/UCDavis_exTecanraw.jpg" width=389 height=300 /></td> | <td><img src="https://static.igem.org/mediawiki/2013/6/66/UCDavis_exTecanraw.jpg" width=389 height=300 /></td> | ||
Line 44: | Line 44: | ||
<tr> | <tr> | ||
<td><img src="https://static.igem.org/mediawiki/2013/c/cf/UCD_database_plate_layout.png" width=400px height=300px></td> | <td><img src="https://static.igem.org/mediawiki/2013/c/cf/UCD_database_plate_layout.png" width=400px height=300px></td> | ||
- | <td>2. Standardized data file (csv) that reports your plate layout | + | <td>2. Standardized data file (csv) that reports your plate layout with information on how each well varies within the experiment. The <a href="http://docs.google.com/spreadsheet/ccc?key=0AuZVn6NXAPHhdHk1MmVKd2tab3ZNd3dWY2ExQ25kbEE#gid=0">linked tabular format</a> that is partly shown here. Sheet two in the link contains a hypothetical example filled in.</td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 50: | Line 50: | ||
<img src="https://static.igem.org/mediawiki/2013/6/6e/UCD_fluo_celldensity.png" width=257px height=300px></td> | <img src="https://static.igem.org/mediawiki/2013/6/6e/UCD_fluo_celldensity.png" width=257px height=300px></td> | ||
<td> | <td> | ||
- | 3. Standardized data file (csv), that reports your fluorescence | + | 3. Standardized data file (csv), that reports your measurements over time (ex: fluorescence, cell density, temperature) in the <a href="http://docs.google.com/spreadsheet/ccc?key=0AuZVn6NXAPHhdE9nMjlRZEJnTFFHM1lpVWltWW9nbXc#gid=0">linked tabular format</a> that is partly shown here. Sheet two in the link contains a hypothetical example filled in. </td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><img src="https://static.igem.org/mediawiki/2013/4/44/UCD_metadata_template.png"></td> | <td><img src="https://static.igem.org/mediawiki/2013/4/44/UCD_metadata_template.png"></td> | ||
- | <td>4. The metadata file (csv) that reports information on your experiment's conditions and settings in the <a href="http://docs.google.com/spreadsheet/ccc?key=0AuZVn6NXAPHhdEE2VFBSdkJ6RzNZXzhiQU9BZnRsSHc#gid=0">linked tabular format</a> that is fully shown here.</td> | + | <td>4. The metadata file (csv) that reports information on your experiment's conditions and settings in the <a href="http://docs.google.com/spreadsheet/ccc?key=0AuZVn6NXAPHhdEE2VFBSdkJ6RzNZXzhiQU9BZnRsSHc#gid=0">linked tabular format</a> that is fully shown here. Sheet two in the link contains a hypothetical example filled in.</td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 62: | Line 62: | ||
</table> | </table> | ||
<p><br /> | <p><br /> | ||
- | |||
</p> | </p> | ||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
</div> | </div> | ||
<div class="floatbox"> | <div class="floatbox"> | ||
Line 91: | Line 69: | ||
<tr> | <tr> | ||
<td> | <td> | ||
- | <a href="http://dilbert.cs.ucdavis.edu/Depot/"><img src="https://static.igem.org/mediawiki/2013/4/4e/ | + | <a href="http://dilbert.cs.ucdavis.edu/Depot/"><img src="https://static.igem.org/mediawiki/2013/4/4e/Visitdepot_UCDavis.jpg" class="blur"></a> |
<a href="http://dilbert.cs.ucdavis.edu/Depot/"><h3>Visit the Depot</h3></a> | <a href="http://dilbert.cs.ucdavis.edu/Depot/"><h3>Visit the Depot</h3></a> | ||
</td> | </td> |
Latest revision as of 02:01, 29 October 2013
Standards in the Depot
Although there have been differing methods of characterizing Biobricks, the vast majority of characterizations use the measurement of fluorescence and cell density in a microplate reader. The standards can accommodate some other types of characterizations, but are best suited to report data as described.
Additionally, The Depot defines an uploadable experiment as: empirical measurements of a response from a single part type in the same construct that are affected by the same set of user-controlled variables.
1. The raw data file (.txt, .csv, .xls, .xlx) from the output of your machine. An example is shown here. | |
2. Standardized data file (csv) that reports your plate layout with information on how each well varies within the experiment. The linked tabular format that is partly shown here. Sheet two in the link contains a hypothetical example filled in. | |
3. Standardized data file (csv), that reports your measurements over time (ex: fluorescence, cell density, temperature) in the linked tabular format that is partly shown here. Sheet two in the link contains a hypothetical example filled in. | |
4. The metadata file (csv) that reports information on your experiment's conditions and settings in the linked tabular format that is fully shown here. Sheet two in the link contains a hypothetical example filled in. | |
The well-IDs follow the following naming system, where the columns are numbered and the rows are capitalized letters. |
Visit the Depot |
Data StandardsSee the Depot's standards and data requirements so you can share your data as well. |
Initial PopulationSee how we initially populated the Depot. |
About the DepotCheck out the motivations behind the Depot. |