22/08/13
From 2013.igem.org
(Difference between revisions)
(→Running sonicated herring sperm DNA on 0.8% gel) |
AliceHaworth (Talk | contribs) |
||
(One intermediate revision not shown) | |||
Line 1: | Line 1: | ||
+ | <div style="font-family:arial;padding:5px;border-radius:5px;border:5px solid #FF2800;"> | ||
+ | {| style="color:#87EA00;background-color:#FFFFFF;" cellpadding="2" cellspacing="2" border="0" bordercolor="#000000" width="100%" align="center" | ||
+ | !align="center"|[[Team:Leicester|Home]] | ||
+ | !align="center"|[[Team:Leicester/Team|Team]] | ||
+ | !align="center"|[https://igem.org/Team.cgi?year=2013&team_name=Leicester Official Team Profile] | ||
+ | !align="center"|[[Team:Leicester/Project|Project]] | ||
+ | !align="center"|[[Team:Leicester/Parts|Parts Submitted to the Registry]] | ||
+ | !align="center"|[[Team:Leicester/Modeling|Modeling]] | ||
+ | !align="center"|[[Team:Leicester/Notebook|Notebook]] | ||
+ | !align="center"|[[Team:Leicester/Safety|Safety]] | ||
+ | !align="center"|[[Team:Leicester/Attributions|Attributions]] | ||
+ | |} | ||
+ | </div> | ||
==Measuring the concentrations of isolated ''P. putida'' DNA from the previous day== | ==Measuring the concentrations of isolated ''P. putida'' DNA from the previous day== | ||
*Measuring concentration using nanodrop | *Measuring concentration using nanodrop | ||
Line 51: | Line 64: | ||
*Volume of sterile water is adjusted appropriately to make up 20ul of sample per well, including 5ul of orange G dye | *Volume of sterile water is adjusted appropriately to make up 20ul of sample per well, including 5ul of orange G dye | ||
[[File:igem_shear_son_220813.jpg]] | [[File:igem_shear_son_220813.jpg]] | ||
+ | *Not visible on the computer file, but picture shows a very slight decrease in sheared/sonificated and unsheared/sonicated samples vs the unsheared/unsonificated control | ||
+ | *The difference is not significant, but the viscosity has changed when mechanically spreading the DNA on polystyrene, though it is not that evident on the gel. | ||
==Making up a sheared/sonicated dilution to leave on bench overnight== | ==Making up a sheared/sonicated dilution to leave on bench overnight== |
Latest revision as of 13:57, 23 August 2013
Home | Team | Official Team Profile | Project | Parts Submitted to the Registry | Modeling | Notebook | Safety | Attributions |
---|
Measuring the concentrations of isolated P. putida DNA from the previous day
- Measuring concentration using nanodrop
- Blanking against buffer
Sample nr. | Concentration ng/ul | 260/280 | 260/230 |
2 | 44 | 1.8 | 1.15 |
4 | 30.6 | 1.8 | 1.29 |
6 | 42.3 | 1.81 | 1.05 |
8 | 35.6 | 1.85 | 1.26 |
10 | 38.2 | 1.84 | 1.28 |
12 | 40.6 | 1.83 | 1.45 |
14 | 39.9 | 1.88 | 1.47 |
16 | 18.5 | 1.17 | 0.67 |
Preparing samples to run on 1% gel
- 500ng of each of the isolated P. putida DNA sample is run on gel
- Volumes are adjusted to 20ul per well accordingly (includes DNA, sterile H2O and OG)
- 5ul of orange G dye is added to each sample
- 5ul of 1kb ladders are used
- For sheared DNA, dilutions were loaded
- 1ul of DNA was diluted in 9ul of 1xTE buffer to make up 10x dilution
- 1ul from 10x dilution was put in 9ul of 1xTE buffer to make up 100x dilution
- Dilutions were nanodropped and the concentration for 100 fold dilution was 121 ng/ul
- 200ng of herring sperm DNA was run on gel
- One lane was left for control, non-sheared DNA, also 100 fold dilution
Running gel of P. putida DNA and Herring sperm DNA
Samples in lanes goes as follows: 1 Kb ladder, 2, 4, 6, 8, 10, 12, 14, 16, 1 kb ladder, 100x dilution of sheared herring sperm DNA, control 100x diluted herring sperm DNA
Running sonicated herring sperm DNA on 0.8% gel
- 3 lanes for running:
- Sheared and sonicated
- Unsheared and sonicated
- Unsheared and unsonicated
- 5ul of 1kb marker is used
- The DNA samples are diluted 100 fold and 200ng of sample is run.
- Volume of sterile water is adjusted appropriately to make up 20ul of sample per well, including 5ul of orange G dye
- Not visible on the computer file, but picture shows a very slight decrease in sheared/sonificated and unsheared/sonicated samples vs the unsheared/unsonificated control
- The difference is not significant, but the viscosity has changed when mechanically spreading the DNA on polystyrene, though it is not that evident on the gel.
Making up a sheared/sonicated dilution to leave on bench overnight
- 500ul of sheared/sonicated DNA
- 500ul of 1xTE
- Mix
- Leave on bench overnight
Incubating sheared/sonicated dilution at 37C on a shaking rack
- 10ul of 1xTE added to 2ul of sheared/sonicated DNA
- Mix
- Incubated overnight at 37C on a shaking rack