Team:SJTU-BioX-Shanghai/Results/Test/Overall
From 2013.igem.org
(Difference between revisions)
(→Overall System) |
(→Plasmid mRFP test) |
||
Line 24: | Line 24: | ||
==Plasmid mRFP test== | ==Plasmid mRFP test== | ||
+ | =Light Gradient= | ||
A gradient of ten different light intensities was established within the sensing range of YF1-FixJ-PFixK2, from zero to saturation (Ohlendorf et al., 2012). | A gradient of ten different light intensities was established within the sensing range of YF1-FixJ-PFixK2, from zero to saturation (Ohlendorf et al., 2012). | ||
+ | =Ensure Similar OD= | ||
But to avoid the discrepancy of growing phase among different experiment groups, bacteria are cultured in darkness to stationary phase (OD600 ≈ 2.2) before they are divided. This procedure takes about 24 hours. And the fluorescence intensity reaches about 28.245 a.u.. | But to avoid the discrepancy of growing phase among different experiment groups, bacteria are cultured in darkness to stationary phase (OD600 ≈ 2.2) before they are divided. This procedure takes about 24 hours. And the fluorescence intensity reaches about 28.245 a.u.. | ||
+ | =Measure mRFP Expression= | ||
Then after another 15 hours’ culture under different blue light intensities, fluorescence intensities are measured again. The result is shown in Figure 2a. Bar height represents the increase of fluorescence intensity between two successive measurements, which corresponds the production rate of mRFP. With the increase of light intensity, we observed a gradual ascend in the expression strength. | Then after another 15 hours’ culture under different blue light intensities, fluorescence intensities are measured again. The result is shown in Figure 2a. Bar height represents the increase of fluorescence intensity between two successive measurements, which corresponds the production rate of mRFP. With the increase of light intensity, we observed a gradual ascend in the expression strength. | ||
Line 35: | Line 38: | ||
Three properties make our sensor-CRISPRi suitable for precise regulation: | Three properties make our sensor-CRISPRi suitable for precise regulation: | ||
- | + | · Under optical saturation, mRFP is produced about twice as fast as it is in the darkness, indicat-ing a relatively wide range for adjusting regulation effect. And the regulation range can be further enlarged by intro-ducing additional gRNAs for the same target. | |
- | + | · The squared Pearson coefficient (R2) of linear fit is calculated to be 0.901. So the expression is stably accelerated as we lift up light intensity (even if the relationship is not strictly linear), making it easier for researchers to locate an optimal regula-tion. | |
- | + | · The variance (standard errors are represented as error bars in Figure 2a) is relatively small. So our system is stable, and a pre-determined working curve can be referenced in later experiments. | |
==Endogenous fadD Test== | ==Endogenous fadD Test== |
Revision as of 01:07, 17 January 2014