Team:BIOINT Mexico/Lab work

From 2013.igem.org

(Difference between revisions)
Line 6: Line 6:
----
----
----
----
 +
 +
'''Experiment 1: Preparation of growth mediums (MRS and LB) (June 5th, 2013)'''
 +
 +
10 Agar LB plates
 +
 +
15 Agar MRS plates
 +
 +
 +
Notes:
 +
*(1) 18.6g of Agar MRS were weighted to prepare 300ml of medium
 +
*(2) 7g of Agar LB were weighted to prepare 200ml of medium
 +
*(1)  5g of A-MRS were diluted in 80ml of distilled water
 +
*Another 5g and 170ml of distilled water were added
 +
*Small lumps were formed in the bottom of the Erlenmeyer flask
 +
*(2) 7g of Agar LB were distilled in 100ml of distilled water
 +
*Further 100ml of distilled water were added
 +
*It wasn’t possible to use a control of the sterilization because there was no autoclave tape
 +
*The autoclave began heating up
 +
*The autoclave valve was lowered
 +
*When the temperature of the autoclave reached 120⁰c, the power was cut to the half
 +
*The vapor cycle ended and the temperature decreased
 +
*The temperature reached 105⁰c and the valve was opened. The mediums were left inside the autoclave until de laminar flow cabinet was unoccupied
 +
*The medium in petri dishes were stored in the refrigerator
 +
*The growth mediums in storage were revised, they do not show signs of contamination
 +
17 MRS Agar
 +
 
 +
9 LB Agar

Revision as of 04:37, 27 September 2013

SmartPro

Smartpro

Igem LogotipoDefinitivo



Lab work



Experiment 1: Preparation of growth mediums (MRS and LB) (June 5th, 2013)

10 Agar LB plates

15 Agar MRS plates


Notes:

  • (1) 18.6g of Agar MRS were weighted to prepare 300ml of medium
  • (2) 7g of Agar LB were weighted to prepare 200ml of medium
  • (1) 5g of A-MRS were diluted in 80ml of distilled water
  • Another 5g and 170ml of distilled water were added
  • Small lumps were formed in the bottom of the Erlenmeyer flask
  • (2) 7g of Agar LB were distilled in 100ml of distilled water
  • Further 100ml of distilled water were added
  • It wasn’t possible to use a control of the sterilization because there was no autoclave tape
  • The autoclave began heating up
  • The autoclave valve was lowered
  • When the temperature of the autoclave reached 120⁰c, the power was cut to the half
  • The vapor cycle ended and the temperature decreased
  • The temperature reached 105⁰c and the valve was opened. The mediums were left inside the autoclave until de laminar flow cabinet was unoccupied
  • The medium in petri dishes were stored in the refrigerator
  • The growth mediums in storage were revised, they do not show signs of contamination

17 MRS Agar

9 LB Agar