+ | '''Experiment 1: Preparation of growth mediums (MRS and LB) (June 5th, 2013)''' | ||
+ | |||
+ | 10 Agar LB plates | ||
+ | |||
+ | 15 Agar MRS plates | ||
+ | |||
+ | |||
+ | Notes: | ||
+ | *(1) 18.6g of Agar MRS were weighted to prepare 300ml of medium | ||
+ | *(2) 7g of Agar LB were weighted to prepare 200ml of medium | ||
+ | *(1) 5g of A-MRS were diluted in 80ml of distilled water | ||
+ | *Another 5g and 170ml of distilled water were added | ||
+ | *Small lumps were formed in the bottom of the Erlenmeyer flask | ||
+ | *(2) 7g of Agar LB were distilled in 100ml of distilled water | ||
+ | *Further 100ml of distilled water were added | ||
+ | *It wasn’t possible to use a control of the sterilization because there was no autoclave tape | ||
+ | *The autoclave began heating up | ||
+ | *The autoclave valve was lowered | ||
+ | *When the temperature of the autoclave reached 120⁰c, the power was cut to the half | ||
+ | *The vapor cycle ended and the temperature decreased | ||
+ | *The temperature reached 105⁰c and the valve was opened. The mediums were left inside the autoclave until de laminar flow cabinet was unoccupied | ||
+ | *The medium in petri dishes were stored in the refrigerator | ||
+ | *The growth mediums in storage were revised, they do not show signs of contamination | ||
+ | 17 MRS Agar | ||
+ | |||
+ | 9 LB Agar |
Revision as of 04:37, 27 September 2013
Lab work
Experiment 1: Preparation of growth mediums (MRS and LB) (June 5th, 2013)
10 Agar LB plates
15 Agar MRS plates
Notes:
- (1) 18.6g of Agar MRS were weighted to prepare 300ml of medium
- (2) 7g of Agar LB were weighted to prepare 200ml of medium
- (1) 5g of A-MRS were diluted in 80ml of distilled water
- Another 5g and 170ml of distilled water were added
- Small lumps were formed in the bottom of the Erlenmeyer flask
- (2) 7g of Agar LB were distilled in 100ml of distilled water
- Further 100ml of distilled water were added
- It wasn’t possible to use a control of the sterilization because there was no autoclave tape
- The autoclave began heating up
- The autoclave valve was lowered
- When the temperature of the autoclave reached 120⁰c, the power was cut to the half
- The vapor cycle ended and the temperature decreased
- The temperature reached 105⁰c and the valve was opened. The mediums were left inside the autoclave until de laminar flow cabinet was unoccupied
- The medium in petri dishes were stored in the refrigerator
- The growth mediums in storage were revised, they do not show signs of contamination
17 MRS Agar
9 LB Agar