Team:Freiburg/Safety/safety forms
From 2013.igem.org
Line 123: | Line 123: | ||
<p id="h4"> a. Risks to the safety and health of team members or others working in the lab? | <p id="h4"> a. Risks to the safety and health of team members or others working in the lab? | ||
</p> | </p> | ||
+ | |||
+ | <p> The biological materials used in our project are not related to pathogenicity and/or toxicity. The E.coli that we use to amplify our plasmids is the safe lab strain K12 which is not pathogenic. The mammalian cell lines we use in cell culture are rated in Germany as RG1. Nevertheless we handle these cells with great caution under sterile conditions. Therefore we do not see expanded risk for our team members and other lab workers. </p> | ||
+ | |||
<p id="h4"> b. Risks to the safety and health of the general public, if released by design or by accident? </p> | <p id="h4"> b. Risks to the safety and health of the general public, if released by design or by accident? </p> | ||
+ | <p> DNA constructs used in this work as well as the genetically modified cells are thought for laboratory work. They should not be able to harm of any organism. Due to this fact we see no risk to safety and health of anyone when coming in contact with our constructs. </p> | ||
<p id="h4"> c. Risks to the environment, if released by design or by accident? </p> | <p id="h4"> c. Risks to the environment, if released by design or by accident? </p> | ||
+ | <p> As described above there is no risk for the environment by release. Even if our DNA constructs are taken up by organisms there is no risk to the environment as the constructs do not transfer any pathogenicity factors or biological fitness advantages. </p> | ||
<p id="h4"> d. Risks to security through malicious misuse by individuals, groups, or countries? </p> | <p id="h4"> d. Risks to security through malicious misuse by individuals, groups, or countries? </p> | ||
- | + | <p> Our system cannot be used for malicious purposes. It is a tool for scientific research and cannot be misused. </p> | |
<p id="h3"> 5. If your project moved from a small-scale lab study to become widely used as a commercial/industrial product, what new risks might arise? (Consider the different categories of risks that are listed in parts a-d of the previous question.) Also, what risks might arise if the knowledge you generate or the methods you develop became widely available? (Note: This is meant to be a somewhat open-ended discussion question.) | <p id="h3"> 5. If your project moved from a small-scale lab study to become widely used as a commercial/industrial product, what new risks might arise? (Consider the different categories of risks that are listed in parts a-d of the previous question.) Also, what risks might arise if the knowledge you generate or the methods you develop became widely available? (Note: This is meant to be a somewhat open-ended discussion question.) | ||
</p> | </p> | ||
+ | |||
+ | <p> Our main protein, Cas9 and its related RNAs, are originating from a pathogen (Streptococcus pyogenes). This bacterium is classified, according to German regulations, to be safety level 2. As we are only dealing with a protein and RNAs, which are not described as a part of any pathogenic or toxic factor of this bacterium, they can be considered as harmless. | ||
+ | This is in accordance to German regulations for biotechnology and the German safety forms. <br><br> | ||
+ | An up-scale of this system would not raise any additional dangers and could be performed under S1 conditions as our small-scale approaches. This is also in accordance to German safety regulations. </p> | ||
+ | |||
<p id="h3"> 6. Does your project include any design features to address safety risks? (For example: kill switches, auxotrophic chassis, etc.) Note that including such features is not mandatory to participate in iGEM, but many groups choose to include them. | <p id="h3"> 6. Does your project include any design features to address safety risks? (For example: kill switches, auxotrophic chassis, etc.) Note that including such features is not mandatory to participate in iGEM, but many groups choose to include them. | ||
</p> | </p> | ||
+ | <p> No, our project does not include any additional safety features. </p> | ||
- | <p id="h3"> | + | <p id="h3"> 7. What safety training have you received (or plan to receive in the future)? Provide a brief description, and a link to your institution’s safety training requirements, if available. |
- | + | ||
- | 7. What safety training have you received (or plan to receive in the future)? Provide a brief description, and a link to your institution’s safety training requirements, if available. | + | |
</p> | </p> | ||
+ | <p> Every team member has received a safety introduction. The introduction was performed by the safety instructor of our facility, Dr. Matias Zurbriggen. It included the handling of hazardous materials and equipment, biological waste disposal and behavior in cases of emergency. Our project was classified as S1 security level by the safety institution of our university. The regulations of the university can be found in the attached file. </p> | ||
<p id="h3"> 8. Under what biosafety provisions will / do you work? | <p id="h3"> 8. Under what biosafety provisions will / do you work? | ||
</p> | </p> | ||
Line 144: | Line 154: | ||
a. Please provide a link to your institution biosafety guidelines. | a. Please provide a link to your institution biosafety guidelines. | ||
</p> | </p> | ||
+ | <p> As the guideline of our institution is not available online we provide a file containing them attached to this email. </p> | ||
<p id="h4"> | <p id="h4"> | ||
b. Does your institution have an Institutional Biosafety Committee, or an equivalent group? If yes, have you discussed your project with them? Describe any concerns they raised with your project, and any changes you made to your project plan based on their review. | b. Does your institution have an Institutional Biosafety Committee, or an equivalent group? If yes, have you discussed your project with them? Describe any concerns they raised with your project, and any changes you made to your project plan based on their review. | ||
</p> | </p> | ||
+ | <p> We discussed our projects extensively with the “Stabsstelle Sicherheit”, the independent biosafety institution of our university. They did not raise any security concerns about our project. For further information see http://www.sicherheit.uni-freiburg.de. </p> | ||
+ | |||
<p id="h4"> | <p id="h4"> | ||
c. Does your country have national biosafety regulations or guidelines? If so, please provide a link to these regulations or guidelines if possible. | c. Does your country have national biosafety regulations or guidelines? If so, please provide a link to these regulations or guidelines if possible. | ||
</p> | </p> | ||
+ | <p> In Germany all biosafety aspects are regulated by the GenTG (Gesetz zur Regulierung der Gentechnik – Gene technology regulation law.) and the GenTSV (Verordnung über die Sicherheitsstufen und Sicherheitsmaßnahmen bei gentechnischen Arbeiten in gentechnischen Anlagen – Regulations for the security levels and security measurements in biotechnological work in biotechnological facilities). | ||
+ | http://www.gesetze-im-internet.de/gentg/index.html | ||
+ | http://www.gesetze-im-internet.de/gentsv/ </p> | ||
+ | |||
<p id="h4"> d. According to the WHO Biosafety Manual, what is the BioSafety Level rating of your lab? (Check the summary table on page 3, and the fuller description that starts on page 9.) If your lab does not fit neatly into category 1, 2, 3, or 4, please describe its safety features [see 2013.igem.org/Safety for help]. | <p id="h4"> d. According to the WHO Biosafety Manual, what is the BioSafety Level rating of your lab? (Check the summary table on page 3, and the fuller description that starts on page 9.) If your lab does not fit neatly into category 1, 2, 3, or 4, please describe its safety features [see 2013.igem.org/Safety for help]. | ||
</p> | </p> | ||
+ | <p> Our lab has been approved for work under safety level 2. All the work we are doing for this project has been classified as safety level 1(considering German regulations) experiments as we are not using any pathogen or toxicity related organism or genetic part. According to the WHO our lab can be rated as biosafety level 2. </p> | ||
<p id="h4"> e. What is the Risk Group of your chassis organism(s), as you stated in question 1? If it does not match the BSL rating of your laboratory, please explain what additional safety measures you are taking. | <p id="h4"> e. What is the Risk Group of your chassis organism(s), as you stated in question 1? If it does not match the BSL rating of your laboratory, please explain what additional safety measures you are taking. | ||
</p> | </p> | ||
+ | <p> We are using Top10 OneShot™ K12 E.coli cells as vector chassis. They are rated level 1 as they do not cause any harm to people if handled correctly. | ||
+ | As a test chassis we were using different mammalian cell lines. We were using CHO (Chinese hamster ovary), HEK293T- (human embryonic kidney), NIH/3T3 cells and HeLa (Henriette Lacks) cells. In Germany these cell lines are classified as BSL 1, in contrast to the USA regulations were they are classifies as BSL 2. The lab in which the team works is accredited to BSL 2. Thus, additional safety levels are not necessary. | ||
+ | |||
+ | <br> | ||
+ | <br> | ||
+ | <br> | ||
+ | |||
+ | Faculty Advisor Name: Prof. Dr. Wilfried Weber <br> | ||
+ | Signature: <br> | ||
+ | </p> | ||
Revision as of 15:18, 1 October 2013
Safety questions
At the beginning of our research we wanted to be aware of all the probable hazards concerning our project. This included that we tried to identify safety issues. Therefore we concentrated on pathogenicity of the microorganisms and cell lines of interest, the datasheets of chemicals probably used during the project (e.g. DNA stains) and the engineered devices and systems. Thus, we orientated on the hints of the iGEM 2013 safety page as well as the safety constraints for genetic engineering given by the “Stabsstelle Sicherheit” of the University of Freiburg. At this point we are obliged to Dr. M. Zurbriggen, who gave us safety instructions before starting our investigations.
1.Please describe the chassis organism(s) you will be using for this project. If you will be using more than one chassis organism, provide information on each of them:
# | Species | Strain no/name | Risk Group | Risk group source link | Disease risk to humans? If so, which disease? |
---|---|---|---|---|---|
1 | E.coli (K12) | TOP10 | 1 | http://apps2.bvl.bund.de/strainwww/protected/main/strain.do?method=detail&theId=49&d-49653-p=null | "Yes. May cause irritation to skin, eyes, and respiratory tract, may affect kidneys. " |
2 | human | HEK293T | 2 (1, according to german guidelines) | http://apps2.bvl.bund.de/cellswww/protected/main/cell.do?method=detail&theId=73&d-49653-p=22 | |
3 | human | HeLa | 2 (1, according to german guidelines) | http://apps2.bvl.bund.de/cellswww/protected/main/cell.do?method=detail&theId=22&d-49653-p=null | |
4 | hamster | CHO-K1 | 1 | http://apps2.bvl.bund.de/cellswww/protected/main/cell.do?method=detail&theId=13&d-49653-p=12 | |
5 | mouse | NIH/3T3 | 1 | http://apps2.bvl.bund.de/cellswww/protected/main/cell.do?method=detail&theId=33&d-49653-p=null |
2. Highest Risk Group Listed
[ ]1
[2] Greater than 1
3. List and describe all new or modified coding regions you will be using in your project. (If you use parts from the 2013 iGEM Distribution without modifying them, you do not need to list those parts.)
Part number. | name | "Where did you get the physical DNA for this part (which lab, synthesis company, etc) " | "What species does this part originally come from? " | "What is the Risk Group of the species? " | "What is the function of this part, in its parent species? " |
---|---|---|---|---|---|
BBa_K1150000 | cas9 | AddGene | Streptococcus pyogenes | 2 | specific immune response |
BBa_K1150001 | vp16 | AG Wilfried Weber, University of Freiburg | Herpes simplex virus | 2 | gene transcription stimulator |
BBa_K1150002 | krab | AG Wilfried Weber, University of Freiburg | Homo sapiens | 1 | repressor of transcriptional activity |
BBa_K1150003 | g9a-sd | AG Jeltsch, University of Stuttgart | Mus musculus | 1 | histone methyl transferase |
BBa_K1150004 | phyb | AG Wilfried Weber, University of Freiburg | Arabidopsis thaliana | 1 | light signaling transducer | BBa_K1150005 | pif6 | AG Wilfried Weber, University of Freiburg | Arabidopsis thaliana | 1 | interacting factor of phyB | BBa_K1150006 | uvr8 | AG Wilfried Weber, University of Freiburg | Arabidopsis thaliana | 1 | light signaling transducer | BBa_K1150007 | cop1 | AG Wilfried Weber, University of Freiburg | Arabidopsis thaliana | 1 | light signaling transducer | BBa_K1150008 | cip | AG Wilfried Weber, University of Freiburg | Arabidopsis thaliana | 1 | light signaling transducer | BBa_K1150009 | cry2 | AG Wilfried Weber, University of Freiburg | Arabidopsis thaliana | 1 | light signaling transducer | BBa_K1150010 | NLS | AG Wilfried Weber, University of Freiburg | AAV2 | 2 | nuclear localization sequence | BBa_K1150011 | SV40 | AG Wilfried Weber, University of Freiburg | Simian-Virus 40 | 2 | viral promoter | BBa_K1150012 | bGH-terminator | AG Wilfried Weber, University of Freiburg | Bos taurus | 1 | terminator of the bovine growth hormone gene | BBa_K1150013 | short linker | AG Wilfried Weber, University of Freiburg | synthesized by Sigma-Aldrich as Oligos | short, flexible linker | BBa_K1150015 | CMV | AG Wilfried Weber, University of Freiburg | Cytomegalievirus | 2 | viralpromoter | BBa_K1150016 | HA-Tag | AG Wilfried Weber, University of Freiburg | synthesized by Sigma-Aldrich as Oligos | Protein sequence tag | BBa_K1150034 | RNA-plasmid | AddGene | Streptococcus pyogenes, Homo sapiens | 2 | specific immune response |
4. Do the biological materials used in your lab work pose any of the following risks? Please describe.
a. Risks to the safety and health of team members or others working in the lab?
The biological materials used in our project are not related to pathogenicity and/or toxicity. The E.coli that we use to amplify our plasmids is the safe lab strain K12 which is not pathogenic. The mammalian cell lines we use in cell culture are rated in Germany as RG1. Nevertheless we handle these cells with great caution under sterile conditions. Therefore we do not see expanded risk for our team members and other lab workers.
b. Risks to the safety and health of the general public, if released by design or by accident?
DNA constructs used in this work as well as the genetically modified cells are thought for laboratory work. They should not be able to harm of any organism. Due to this fact we see no risk to safety and health of anyone when coming in contact with our constructs.
c. Risks to the environment, if released by design or by accident?
As described above there is no risk for the environment by release. Even if our DNA constructs are taken up by organisms there is no risk to the environment as the constructs do not transfer any pathogenicity factors or biological fitness advantages.
d. Risks to security through malicious misuse by individuals, groups, or countries?
Our system cannot be used for malicious purposes. It is a tool for scientific research and cannot be misused.
5. If your project moved from a small-scale lab study to become widely used as a commercial/industrial product, what new risks might arise? (Consider the different categories of risks that are listed in parts a-d of the previous question.) Also, what risks might arise if the knowledge you generate or the methods you develop became widely available? (Note: This is meant to be a somewhat open-ended discussion question.)
Our main protein, Cas9 and its related RNAs, are originating from a pathogen (Streptococcus pyogenes). This bacterium is classified, according to German regulations, to be safety level 2. As we are only dealing with a protein and RNAs, which are not described as a part of any pathogenic or toxic factor of this bacterium, they can be considered as harmless.
This is in accordance to German regulations for biotechnology and the German safety forms.
An up-scale of this system would not raise any additional dangers and could be performed under S1 conditions as our small-scale approaches. This is also in accordance to German safety regulations.
6. Does your project include any design features to address safety risks? (For example: kill switches, auxotrophic chassis, etc.) Note that including such features is not mandatory to participate in iGEM, but many groups choose to include them.
No, our project does not include any additional safety features.
7. What safety training have you received (or plan to receive in the future)? Provide a brief description, and a link to your institution’s safety training requirements, if available.
Every team member has received a safety introduction. The introduction was performed by the safety instructor of our facility, Dr. Matias Zurbriggen. It included the handling of hazardous materials and equipment, biological waste disposal and behavior in cases of emergency. Our project was classified as S1 security level by the safety institution of our university. The regulations of the university can be found in the attached file.
8. Under what biosafety provisions will / do you work?
a. Please provide a link to your institution biosafety guidelines.
As the guideline of our institution is not available online we provide a file containing them attached to this email.
b. Does your institution have an Institutional Biosafety Committee, or an equivalent group? If yes, have you discussed your project with them? Describe any concerns they raised with your project, and any changes you made to your project plan based on their review.
We discussed our projects extensively with the “Stabsstelle Sicherheit”, the independent biosafety institution of our university. They did not raise any security concerns about our project. For further information see http://www.sicherheit.uni-freiburg.de.
c. Does your country have national biosafety regulations or guidelines? If so, please provide a link to these regulations or guidelines if possible.
In Germany all biosafety aspects are regulated by the GenTG (Gesetz zur Regulierung der Gentechnik – Gene technology regulation law.) and the GenTSV (Verordnung über die Sicherheitsstufen und Sicherheitsmaßnahmen bei gentechnischen Arbeiten in gentechnischen Anlagen – Regulations for the security levels and security measurements in biotechnological work in biotechnological facilities). http://www.gesetze-im-internet.de/gentg/index.html http://www.gesetze-im-internet.de/gentsv/
d. According to the WHO Biosafety Manual, what is the BioSafety Level rating of your lab? (Check the summary table on page 3, and the fuller description that starts on page 9.) If your lab does not fit neatly into category 1, 2, 3, or 4, please describe its safety features [see 2013.igem.org/Safety for help].
Our lab has been approved for work under safety level 2. All the work we are doing for this project has been classified as safety level 1(considering German regulations) experiments as we are not using any pathogen or toxicity related organism or genetic part. According to the WHO our lab can be rated as biosafety level 2.
e. What is the Risk Group of your chassis organism(s), as you stated in question 1? If it does not match the BSL rating of your laboratory, please explain what additional safety measures you are taking.
We are using Top10 OneShot™ K12 E.coli cells as vector chassis. They are rated level 1 as they do not cause any harm to people if handled correctly.
As a test chassis we were using different mammalian cell lines. We were using CHO (Chinese hamster ovary), HEK293T- (human embryonic kidney), NIH/3T3 cells and HeLa (Henriette Lacks) cells. In Germany these cell lines are classified as BSL 1, in contrast to the USA regulations were they are classifies as BSL 2. The lab in which the team works is accredited to BSL 2. Thus, additional safety levels are not necessary.
Faculty Advisor Name: Prof. Dr. Wilfried Weber
Signature: