Team:TU-Eindhoven/MRIProcessing
From 2013.igem.org
Pascalaldo (Talk | contribs) |
JacquesErnes (Talk | contribs) (→Methods) |
||
(48 intermediate revisions not shown) | |||
Line 3: | Line 3: | ||
=MRI Data Processing= | =MRI Data Processing= | ||
- | {{:Team:TU-Eindhoven/Template:Lead}}Until recently, the most common way of generating MRI contrast was | + | {{:Team:TU-Eindhoven/Template:Lead}}Until recently, the most common way of generating MRI contrast was to use heavy metal based contrast agents. Examples of these are the commercially available Gadolinium(III) based Magnevist and the Iron Oxide based Resovist. A downside of using heavy metals is the toxicity of the agents in the human body{{:Team:TU-Eindhoven/Template:Ref | id=GNSF | author=T Grobner |
+ | and FC Prischl | title=Gadolinium and nephrogenic systemic fibrosis| journal=Kidney International | edition=72 | pages=260–264 | year=2007 }}{{:Team:TU-Eindhoven/Template:Ref | id=Gsrf34 | author=Ihsan Ergün, Kenan Keven, et all. | title=The safety of gadolinium in patients with stage 3 and 4 renal failure | journal=Nephrology Dialysis Transplantation | edition=21 | pages=697-700 | year=2006 }}{{:Team:TU-Eindhoven/Template:Ref | id=Gint | author=I. Buhaescu and H. Izzedine | title=Gadolinium-induced nephrotoxicity | journal=The International Journal of Clinical Practice | edition=62 | pages=1113-1118 | year=2008 }}. Fortunately, a new type of MRI has been developed, which allows for the use of organic compounds as contrast agent.{{:Team:TU-Eindhoven/Template:LeadEnd}} | ||
+ | ==The Principle== | ||
{{:Team:TU-Eindhoven/Template:Float | position=right | size=4 }} | {{:Team:TU-Eindhoven/Template:Float | position=right | size=4 }} | ||
{{:Team:TU-Eindhoven/Template:Image | filename=CESTExplaination.jpg}} | {{:Team:TU-Eindhoven/Template:Image | filename=CESTExplaination.jpg}} | ||
- | {{:Team:TU-Eindhoven/Template:FloatEnd | caption=a) and b) Solute protons are saturated at their specific resonance frequency in the proton spectrum, this saturation is then transferred to water. c) Measurement of normalized water saturation, the Z-spectrum. d) result of the asymmetry analysis of the Z-spectrum. | + | {{:Team:TU-Eindhoven/Template:FloatEnd | caption=a) and b) Solute protons are saturated at their specific resonance frequency in the proton spectrum, this saturation is then transferred to water. c) Measurement of normalized water saturation, the Z-spectrum. d) result of the asymmetry analysis of the Z-spectrum. {{:Team:TU-Eindhoven/Template:RefAgain | id=vanZijlCEST }} | id=CESTExplaination }} |
- | + | This new type of MRI goes by the name Chemical Exchange Saturation Transfer MRI or CEST MRI{{:Team:TU-Eindhoven/Template:Ref | id=vanZijlCEST | author=van Zijl, Peter, and Nirbhay N. Yadav. | title=Chemical exchange saturation transfer (CEST): what is in a name and what isn't?. | journal=Magnetic Resonance in Medicine | edition=65.4 | pages=8927-948 | year=2011 }}{{:Team:TU-Eindhoven/Template:Ref | id=LiuCEST | author=Liu, Guanshu, et al. | title=Nuts and bolts of chemical exchange saturation transfer MRI. | journal=NMR in Biomedicine | edition= | pages= | year=2013 }}{{:Team:TU-Eindhoven/Template:Ref | id=GiladGene | author=Gilad, Assaf A., et al. | title=MRI reporter genes. | journal=Journal of Nuclear Medicine | edition=49.12 | pages=1905-1908 | year=2008 }}. The principle behind this technique is based on compounds that contain pools of exchangeable protons that can be selectively saturated using radio frequency irradiation. Upon proton exchange with bulk water, these compounds can be indirectly visualized by measuring the bulk water. The amino acids Lysine, Arginine, Threonine and Serine contain these exchangeable protons and polypeptides containing those amino acids in abundance are therefore potential contrast agents {{:Team:TU-Eindhoven/Template:Ref | id=GoffeneyCEST | author=Goffeney, Nicholas, et al. | title=Sensitive NMR detection of cationic-polymer-based gene delivery systems using saturation transfer via proton exchange. | journal=Journal of the American Chemical Society | edition=123.35 | pages=8628-8629 | year=2001 }} {{:Team:TU-Eindhoven/Template:Ref | id=GiladCEST | author=Gilad, Assaf A., et al. | title=Artificial reporter gene providing MRI contrast based on proton exchange. | journal=Nature biotechnology | edition=25.2 | pages=217-219 | year=2007 }}. Another advantage of CEST MRI is that different kinds of protons (e.g. amide and hydroxide protons) can be distinguished, which allows for 'multi-color' imaging when using multiple contrast agents simultaneously {{:Team:TU-Eindhoven/Template:Ref | id=McMahonMulticolor | author=McMahon, Michael T., et al. | title=New 'multicolor' polypeptide diamagnetic chemical exchange saturation transfer (DIACEST) contrast agents for MRI. | journal=Magnetic Resonance in Medicine | edition=60.4 | pages=803-812 | year=2008 }}. | |
- | This new type of MRI goes by the name Chemical Exchange Saturation Transfer MRI or CEST MRI. The principle behind this technique is based on compounds that contain pools of exchangeable protons that can be selectively saturated using | + | |
+ | ==Methods== | ||
+ | This theory can be used to scan our library of potential contrast agents ([[Team:TU-Eindhoven/Production |Protein Selection]]). Hereto the proteins were (aerobically) over expressed in BL21 using a pET28a vector with a T7 promoter. The bacteria were spun down and fixed in PFA. The entire pellet (bacteria containing our proteins) was then measured in a 7 Tesla Bruker MRI machine. First, the correct water frequency was determined, the machine was shimmed, i.e. a homogeneous magnetic field was created. The first measurement was a T<sub>2</sub> weighted image for general orientation. Subsequently local shimming was performed on each of the separate pellets. For the final measurements, the saturation pulse was set to vary from $\pm -4 ppm$ to $\pm +4 ppm$ (relative to water), the measurements were averaged over 8 separate scans. Also a $S_{0}$ (without saturation pulse) image was taken. | ||
==Processing== | ==Processing== | ||
- | To detect | + | To detect the CEST effect of our proteins a number of processing steps are required. First of all, the imaging should be taken at different frequencies of the saturation pulse. This way the signal at different chemical shifts can be measured. When bulk water is set to 0 ppm, the signal plot will be roughly symmetric around zero, since saturation pulses will excite the bulk water in a similar way when the absolute shift is equal. This also implies that when the signals with a negative shift from the bulk water are compared with the signals with a positive shift, asymmetry can be detected. The CEST effect is precisely what causes this asymmetry in the signal plot, due to the chemical shift of the CEST compounds being different from the chemical shift of water. Therefore, when the absolute shift from the bulk water of two saturation pulses is equal, this does not mean the absolute shift from the CEST compound is equal and the CEST protons will in one case hardly saturate at all (depending on its shift from bulk water of course). |
{{:Team:TU-Eindhoven/Template:Float | position=left | size=8 }} | {{:Team:TU-Eindhoven/Template:Float | position=left | size=8 }} | ||
Line 22: | Line 26: | ||
{{:Team:TU-Eindhoven/Template:FloatEnd | caption=Equations for analyzing the CEST MRI data. | id=MTRasymEquations }} | {{:Team:TU-Eindhoven/Template:FloatEnd | caption=Equations for analyzing the CEST MRI data. | id=MTRasymEquations }} | ||
+ | <br /><br /> | ||
- | Putting this principle into practice | + | Putting this principle into practice requires some processing steps. First of all, the asymmetric comparison should be conducted as shown in {{:Team:TU-Eindhoven/Template:Figure | id=MTRasymEquations }}. Where the MTR<sub>asym</sub> is the asymmetry in the z-spectrum. Furthermore, $S_{0}$ and $S_{w}^{\pm\Delta\omega_{sw}}$ are, respectively, the water signals without saturation and with saturation at $\Delta\omega_{sw}$ from bulk water. The PTE is the Proton Transfer Enhancement, which gives an indication of the sensitivity of an agent, independent of the concentration. In this research, the concentration was not measured accurately, but the mass of cell pellet was aimed to be kept constant, so the MTR<sub>asym</sub> plots can still be compared quite well. |
- | To eliminate the background signal of other | + | To eliminate the background signal of other Lysine and Arginine rich proteins, the asymmetric plots of the potential agents were compared to the asymmetric plots of a control sample, where no protein was over-expressed. In practice this can be compared to using an MRI image of human tissue without contrast agent as control for an image of tissue with contrast agent. This comparison was done in two different ways, one option results in the absolute difference compared to the control sample. The other method is relatively comparing the samples ({{:Team:TU-Eindhoven/Template:Figure | id=ContrastComparison }}). |
{{:Team:TU-Eindhoven/Template:Float | position=left | size=12 }} | {{:Team:TU-Eindhoven/Template:Float | position=left | size=12 }} | ||
Line 34: | Line 39: | ||
$$ | $$ | ||
</html> | </html> | ||
- | {{:Team:TU-Eindhoven/Template:FloatEnd | caption= | + | {{:Team:TU-Eindhoven/Template:FloatEnd | caption=Comparison of agent samples and the control sample. | id=ContrastComparison }} |
==Results== | ==Results== | ||
+ | When the previously described processing steps are applied to the MRI results of this research, the following graphs can be acquired. {{:Team:TU-Eindhoven/Template:Figure | id=AllMRIGraphs}} shows the MTR<sub>asym</sub>, $C_{abs}$ (Absolute Difference) and $C_{rel}$ (Relative Difference) graphs for all potential contrast agents that were tested. | ||
{{:Team:TU-Eindhoven/Template:Float | position=left | size=12 }} | {{:Team:TU-Eindhoven/Template:Float | position=left | size=12 }} | ||
{{:Team:TU-Eindhoven/Template:Image | filename=allMRIGraphs.png}} | {{:Team:TU-Eindhoven/Template:Image | filename=allMRIGraphs.png}} | ||
- | {{:Team:TU-Eindhoven/Template:FloatEnd | caption= | + | {{:Team:TU-Eindhoven/Template:FloatEnd | caption=The MTR<sub>asym</sub>, absolute contrast and relative contrast of all potential CEST contrast agents. | id=AllMRIGraphs }} |
+ | Lysine protons are predicted to show contrast at a shift of $\pm 3.7 ppm$ whereas arginine should produce contrast at $\pm 2.0 ppm$. Using this information it can be readily seen that ''1PJN'' ([http://parts.igem.org/Part:BBa_K1123015 BBa_K1123015]) and ''Poly(KS)'' ([http://parts.igem.org/Part:BBa_K1123021 BBa_K1123021]) both exhibit (Lysine-)CEST contrast. It should be noted that for more reliable results, more control samples should be taken into account. Furthermore the determination of the concentration of the agents should be carried out more precisely. However, due to the strange nature of the proteins, this has shown to be rather difficult in practice. But even using one control sample, quite clear results were achieved for the Lysine contrast. {{:Team:TU-Eindhoven/Template:Figure | id=LysineContrastPlot}} shows the calculated contrasts (both absolute and relative) and the Lysine ratio of the agents, which gives an indication of how much contrast to expect. Here the agents with a high Lysine ratio express high Lysine contrast, which comes across with our expectations. However, the high contrast of Poly(TK) could be caused by other factors, since the contrast graphs in {{:Team:TU-Eindhoven/Template:Figure | id=AllMRIGraphs}} do not show clear peaks at $\pm 3.7 ppm$. For Arginine contrast, it is not that simple. The peak is expected at $\pm 2.0 ppm$, which is considerably closer to the frequency of bulk water and is therefore more sensitive to noise. The same analysis as for Lysine is shown in {{:Team:TU-Eindhoven/Template:Figure | id=ArginineContrastPlot}}, but here no clear correlation can be seen. However, looking at the graphs in {{:Team:TU-Eindhoven/Template:Figure | id=AllMRIGraphs}} some peaks can be seen around 2.0 ppm, but no good conclusions can be drawn, since the Arginine protons can not be satisfactory distinguished from the rest of the protons. | ||
+ | |||
+ | |||
+ | {{:Team:TU-Eindhoven/Template:Float | position=left | size=6 }} | ||
+ | {{:Team:TU-Eindhoven/Template:Image | filename=LysineContrastPlot.jpg}} | ||
+ | {{:Team:TU-Eindhoven/Template:FloatEnd | caption=Lysine contrast of all tested contrast agents. | id=LysineContrastPlot }} | ||
+ | {{:Team:TU-Eindhoven/Template:Float | position=right | size=6 }} | ||
+ | {{:Team:TU-Eindhoven/Template:Image | filename=ArginineContrastPlot.jpg}} | ||
+ | {{:Team:TU-Eindhoven/Template:FloatEnd | caption=Arginine contrast of all tested contrast agents. | id=ArginineContrastPlot }} | ||
+ | |||
+ | |||
+ | <br /> | ||
+ | |||
+ | ==Conclusion== | ||
+ | All in all, the most promising candidate agent seems to be ''1PJN'' ([http://parts.igem.org/Part:BBa_K1123015 BBa_K1123015]). The lysine peak of this agent is clearly distinguishable from the rest of the signal. As a Arginine based compound, no clear results have been achieved and therefore no recommendation can be given, other than that the Arginine based agents are less suitable for generating contrast in general. It is therefore our recommendation to use lysine based agents, such as ''1PJN''. Only for multicolor MRI or imaging lysine rich areas can Arginine agents be useful. Another conclusion that can be drawn from the MRI results, is that Poly(KS) has actually been expressed in the bacteria. This is contradictory to the other lab results, where no traces of Poly(KS) on SDS-Page gels were found. The most obvious explanation for these results, is that only a very small part of the Poly(KS) chain was created, which is to be expected due to the largely repetitive and non-optimal DNA of the construct. | ||
==References== | ==References== |
Latest revision as of 12:37, 26 October 2013
Contents |
MRI Data Processing
Until recently, the most common way of generating MRI contrast was to use heavy metal based contrast agents. Examples of these are the commercially available Gadolinium(III) based Magnevist and the Iron Oxide based Resovist. A downside of using heavy metals is the toxicity of the agents in the human bodyGNSFT Grobner and FC Prischl, Gadolinium and nephrogenic systemic fibrosis. Kidney International 72, 260–264 (2007)Gsrf34Ihsan Ergün, Kenan Keven, et all., The safety of gadolinium in patients with stage 3 and 4 renal failure. Nephrology Dialysis Transplantation 21, 697-700 (2006)GintI. Buhaescu and H. Izzedine, Gadolinium-induced nephrotoxicity. The International Journal of Clinical Practice 62, 1113-1118 (2008). Fortunately, a new type of MRI has been developed, which allows for the use of organic compounds as contrast agent.
The Principle
Methods
This theory can be used to scan our library of potential contrast agents (Protein Selection). Hereto the proteins were (aerobically) over expressed in BL21 using a pET28a vector with a T7 promoter. The bacteria were spun down and fixed in PFA. The entire pellet (bacteria containing our proteins) was then measured in a 7 Tesla Bruker MRI machine. First, the correct water frequency was determined, the machine was shimmed, i.e. a homogeneous magnetic field was created. The first measurement was a T2 weighted image for general orientation. Subsequently local shimming was performed on each of the separate pellets. For the final measurements, the saturation pulse was set to vary from $\pm -4 ppm$ to $\pm +4 ppm$ (relative to water), the measurements were averaged over 8 separate scans. Also a $S_{0}$ (without saturation pulse) image was taken.
Processing
To detect the CEST effect of our proteins a number of processing steps are required. First of all, the imaging should be taken at different frequencies of the saturation pulse. This way the signal at different chemical shifts can be measured. When bulk water is set to 0 ppm, the signal plot will be roughly symmetric around zero, since saturation pulses will excite the bulk water in a similar way when the absolute shift is equal. This also implies that when the signals with a negative shift from the bulk water are compared with the signals with a positive shift, asymmetry can be detected. The CEST effect is precisely what causes this asymmetry in the signal plot, due to the chemical shift of the CEST compounds being different from the chemical shift of water. Therefore, when the absolute shift from the bulk water of two saturation pulses is equal, this does not mean the absolute shift from the CEST compound is equal and the CEST protons will in one case hardly saturate at all (depending on its shift from bulk water of course).
Putting this principle into practice requires some processing steps. First of all, the asymmetric comparison should be conducted as shown in . Where the MTRasym is the asymmetry in the z-spectrum. Furthermore, $S_{0}$ and $S_{w}^{\pm\Delta\omega_{sw}}$ are, respectively, the water signals without saturation and with saturation at $\Delta\omega_{sw}$ from bulk water. The PTE is the Proton Transfer Enhancement, which gives an indication of the sensitivity of an agent, independent of the concentration. In this research, the concentration was not measured accurately, but the mass of cell pellet was aimed to be kept constant, so the MTRasym plots can still be compared quite well.
To eliminate the background signal of other Lysine and Arginine rich proteins, the asymmetric plots of the potential agents were compared to the asymmetric plots of a control sample, where no protein was over-expressed. In practice this can be compared to using an MRI image of human tissue without contrast agent as control for an image of tissue with contrast agent. This comparison was done in two different ways, one option results in the absolute difference compared to the control sample. The other method is relatively comparing the samples ().
Results
When the previously described processing steps are applied to the MRI results of this research, the following graphs can be acquired. shows the MTRasym, $C_{abs}$ (Absolute Difference) and $C_{rel}$ (Relative Difference) graphs for all potential contrast agents that were tested.
Conclusion
All in all, the most promising candidate agent seems to be 1PJN ([http://parts.igem.org/Part:BBa_K1123015 BBa_K1123015]). The lysine peak of this agent is clearly distinguishable from the rest of the signal. As a Arginine based compound, no clear results have been achieved and therefore no recommendation can be given, other than that the Arginine based agents are less suitable for generating contrast in general. It is therefore our recommendation to use lysine based agents, such as 1PJN. Only for multicolor MRI or imaging lysine rich areas can Arginine agents be useful. Another conclusion that can be drawn from the MRI results, is that Poly(KS) has actually been expressed in the bacteria. This is contradictory to the other lab results, where no traces of Poly(KS) on SDS-Page gels were found. The most obvious explanation for these results, is that only a very small part of the Poly(KS) chain was created, which is to be expected due to the largely repetitive and non-optimal DNA of the construct.
References