Team:TU-Delft/BandAid

From 2013.igem.org

Revision as of 12:28, 4 October 2013 by Jfkooijman (Talk | contribs)

Band Aid

The Band Aid Modeling is related to the final application of our project. Specifically, we are going to use a band aid in which E. coli will be added. By locating the band aid on the wound, the S. aureus should be detected and killed (Figure 1).

                                                                        Figure 1: Band Aid Application

As, it is already known, S. aureus is a pathogenic bacterium that utilizes quorum sensing (QS), a cell-to-cell signalling mechanism, to enhance its ability to cause disease[1]. The communication is succeeded through small peptides known as AIPs. We engineered the receiver part of S. aureus to E. coli in order to be able for the last to detect AIPs produced by S. aureus.

The main purpose in the band aid modeling is to answer questions like these mentioned underneath:

  1. How many pores are necessary in order to be possible for the peptide to be released?
  2. If the MRSA is detected, is the amount of the produced peptide enough to kill it ?

We start by making a model of the AIP quorum sensing to answer the first question. Then a second model is made to answer the second question with respect to the amount of peptides.

Differential Equations

Our model consists of two Populations:
  1. Sender: The S. aureus Population
  2. Receiver: The E. coli Population

For our model we made the following assumptions:
  1. The S. aureus population grows exponentially.
  2. The E. coli population is constant.
  3. The AIP concentration in both populations is modeled as homogeneous (perfectly mixed). This removes the need of a space model for the populations.
  4. The membrane assumed in 47mm diameter and 0.1μm pore size.
  5. No hydrophobic/hydrophilic interactions between membrane and the AIPs are taken into account.
The differential equations related to each population are represented below.
Sender: S. aureus Population

Figure 2:Sender [1]


Receiver: E. coli Population

        


Note that in the above equation of the permeability the distance is expressed in the ratio of the pore sizes. For example the distance between pores can be 5 times the pore diameter.

Parameters

The references [1][2] used dimensionless variables and parameters. However, to be able to add equations to these models, units must be added. This is done by picking dimensionless values in or resulting from this model and use the known value with dimension to find out the used dimensions of the model.

In the model three units must be determined: the units of time and concentration. This is most easily done by plotting from the resulting model the AIPs over time. However, little is known on the typical concentration of AIPs and the time needed to reach these concentrations. Therefore, we used the quorum sensing system of gram negative bacteria (AHL molecules) as a reference and assume that the order of concentrations is the same for the AIP system.

From the model of [7] it is seen that a concentration of 120 nm is representative in a growth from 1 cell to 1 OD in 100 hours. This final concentration is reached in 45 hours. These two data are used to fit to dimension to the model. These are shown in the table below.

To estimate the growth parameters, we set the K to 1, since the capacity is equal to one OD. The growth rate is set in such a manner to fit the doubling time of S. aureus[8].

Parameter Value Description Units
s 0.02 Ratio of basal to QS transcription -
v 0.05 mRNA transcription rate sec-1
l 1 protein degradation sec-1
f 1 agrA activation nM-2sec-2
g1 1 unbinding AIP from AgrC sec-1
ks 0.08 AgrD loss through AIP production nM-1sec-1
ka 80 AIP production nM-2sec-2
la 1 Natural AIP degradation sec-1
h 0.08 receptor loss through AIP binding nM-1sec-1
gij 1 AIP from Population i unbinding from Population j sec-1
bij 1 AIP binding from Population i to Population j -
ba 1 Ratio of cognate AIP binding in Population 2 to Population 1 -
u 1 Diassociation active AgrA from the DNA binding site sec-1
r 1/2/3600 growth rate
K 1 capacity
D 8e-4 diffusion coefficient of the membrane
A 20000 Area of the membrane
pore size 0.22 membrane pore size 0.001

Variables

The following variables were used in the equations:

Variable Description Unit
Mi mRna concentration in Population i nM
Ai agrA concentration in Population i nM
Si agrD concentration in Population i nM
ai AIP concentration in Population i nM
Ri agrC concentration in Population i nM
Pi Proportion of cells that are upregulated in S. aureus population -
Population Population size of S. aureus OD

Results

Peptide production model

Instead of a complex model a simple calculation is done using the modeling results of the combined system. From this model the total amount of peptides produced is estimated to be 18,000 molecules/cell. If we now calculate this to a concentration in the medium of the E. coli, we can relate this concentration to the determined MIC values. In this manner we do not directly calculate the effect of the volume of the population of S. aureus or losing peptides or the growth of S. aureus. It is therefore an optimistic estimation, which is done in Figure 3.

Discussion

With these results we can give answer to the questions stated above:

  1. How many pores are necessary in order to be possible for the peptide to be released?
  2. If the MRSA is detected, is the amount of the produced peptide enough to kill it ?

    The result is that in 1 OD 0.03μM (30 nM) of peptide can be produced. This is too low, since signiferin has an MIC of 1μM. This would mean that in our current circuit we would need to have 33 OD, or to be exact 33*109 cells/ml. This is however not feasible and therefore a major hurdle to implement the system in a Band-aid.

    One of the solutions to this is to synthesizing peptides. We showed that we could alter the properties to our needs, i.e. making the peptides less toxic to humans. In the same manner you can also work on making the MIC value lower. This way having an MIC in the range of nanomolars is not infeasible. Furthermore, from the sensitivity analysis it shows that the concentration can be increased by slowing down the timer. This way the final concentration of the peptide can be increased.