Team:Calgary/Sandbox/Notebook/Protocols/OvernightCultures
From 2013.igem.org
(Difference between revisions)
Azzucoloto (Talk | contribs) m |
|||
(2 intermediate revisions not shown) | |||
Line 6: | Line 6: | ||
<h2> Reagents and Materials (per culture prepared):</h2> | <h2> Reagents and Materials (per culture prepared):</h2> | ||
<ul> | <ul> | ||
- | <li> 10mL culture tube. Use 16mm x 160mm or 16mm x 125mm</li> | + | <li>10mL culture tube. Use 16mm x 160mm or 16mm x 125mm</li> |
- | <li> | + | <li>5mL LB</li> |
- | <li> | + | <li>5μL 1000X antibiotics</li> |
- | <li> Single colonies on a plate (best not to start an overnight from a glycerol stock)</li> | + | <li>Single colonies on a plate (best not to start an overnight from a glycerol stock)</li> |
</ul> | </ul> | ||
<h2>Protocol</h2> | <h2>Protocol</h2> | ||
<ol> | <ol> | ||
- | <li> Add 3mL sterile/autoclaved LB in a 15mL Falcon tube | + | <li>Add 3mL sterile/autoclaved LB in a 15mL Falcon tube</li> |
- | <li> Pipet 3μL of 1000X antibiotic into the LB | + | <li>Pipet 3μL of 1000X antibiotic into the LB</li> |
- | <li> Select a single colony using a sterile toothpick or pipette tip | + | <li>Select a single colony using a sterile toothpick or pipette tip</li> |
- | <li> Place toothpick or pipette tip in the culture tube and stir | + | <li>Place toothpick or pipette tip in the culture tube and stir</li> |
- | <li> Remove toothpick, or in the case of a pipette tip, leave in the tube | + | <li>Remove toothpick, or in the case of a pipette tip, leave in the tube</li> |
<li>Place culture tube in incubator at 37 degrees Celsius overnight shaking vigorously (250 RPM)</li> | <li>Place culture tube in incubator at 37 degrees Celsius overnight shaking vigorously (250 RPM)</li> | ||
</ol> | </ol> |
Latest revision as of 01:25, 18 September 2013
Overnight Cultures
Reagents and Materials (per culture prepared):
- 10mL culture tube. Use 16mm x 160mm or 16mm x 125mm
- 5mL LB
- 5μL 1000X antibiotics
- Single colonies on a plate (best not to start an overnight from a glycerol stock)
Protocol
- Add 3mL sterile/autoclaved LB in a 15mL Falcon tube
- Pipet 3μL of 1000X antibiotic into the LB
- Select a single colony using a sterile toothpick or pipette tip
- Place toothpick or pipette tip in the culture tube and stir
- Remove toothpick, or in the case of a pipette tip, leave in the tube
- Place culture tube in incubator at 37 degrees Celsius overnight shaking vigorously (250 RPM)