The iGEM-Team UC-Davis 2013 wants to develop and implement an experimental data depot for biobrick characterization data and kindly asked us to collaborate with them. We tested their promoter characterization protocols on the  
The iGEM-Team UC-Davis 2013 wants to develop and implement an experimental data depot for biobrick characterization data and kindly asked us to collaborate with them. We tested their promoter characterization protocols on the  
-
[http://parts.igem.org/Promoters/Catalog/Anderson Anderson promoter collection] J230100-J230119. These biobricks contain the information for the red fluorescent protein and can easily be characterized via fluorescence measurements.
+
[http://parts.igem.org/Promoters/Catalog/Anderson Anderson promoter collection] J230100-J230119. The plasmid backbone of these biobricks J61002 is very suitable for promoter insertion between the XbaI and SpeI sites, which places the promoter upstream of a red fluorescent protein (RFP)gene. Through the promoter, RFP is expressed more frequently or less, while the promoter strength can easily be characterized via fluorescence measurements.
 +
<br>
 +
<br>
<br>
<br>
Our team focused mainly on the second half of the collection, which comprises promoters with the below listed strengths.
Our team focused mainly on the second half of the collection, which comprises promoters with the below listed strengths.
-
 
+
</p>
 +
<div align="center">
{| class="wikitable" style="text-align:center" border="0" cellpadding="5" cellspacing="0" align="center"
{| class="wikitable" style="text-align:center" border="0" cellpadding="5" cellspacing="0" align="center"
!Biobrick number
!Biobrick number
Line 147: Line 152:
   
   
|}
|}
 +
</div>
<p align="justify">
<p align="justify">
We carried out an extended, 18-hour experiment, monitoring cell density through absorbance measurement and promoter strength by way of fluorescence emission. The results are shown subsequently.
We carried out an extended, 18-hour experiment, monitoring cell density through absorbance measurement and promoter strength by way of fluorescence emission. The results are shown subsequently.

Revision as of 18:01, 3 October 2013



Collaborations


Abstract

Beside the research into the project it is important to collaborate with other iGEM teams to support them. This support can be carried out in different ways, for example an exchange via a skype interview or characterize the other part of the other team. In the following description we list our collaborations between us and other teams.


iGEM-Team York_UK

IGEM Bielefeld 2013 collaboration York UK.jpg

Because of the fact that both teams do research into microbial fuel cells we get in touch and talked about our projects. We get to know that York had problems with cloning the mtrCAB cluster and invested a lot of time to solve this problems. Because of the fact that time was running we decided to help York. We already designed our MFC and tested different constructions which one is the best to use. We constructed a MFC specially adapted to the requirements of York and wrote an instruction how to operate with the MFC. In addition we put nafion membranes, gaskets, carbon electrodes and injectors into a package and send it to York. We hope that this support helped York to generate good results and finish their project.



iGEM-Team NRP-UEA-Norwich

IGEM Bielefeld 2013 collaboration NRP UEA iGEM 2013.jpg

The iGEM-Team from Norwich developed a biosensor which enable the identification of antimycin-producing strains of streptomyctes. Therefore they asked us to send them soil samples from Bielefeld. Of course we took samples of soil and send them to Norwich. The interesting soil samples of Bielefeld are shown below. We hope that our soil samples helped Norwich.

Figure 1: Sample No. 33
Figure 2: Sample No. 34
Figure 3: Soil from which the samples were taken


iGEM-Team UC Davis


IGEM Bielefeld UCDavisBanner.jpg


The iGEM-Team UC-Davis 2013 wants to develop and implement an experimental data depot for biobrick characterization data and kindly asked us to collaborate with them. We tested their promoter characterization protocols on the [http://parts.igem.org/Promoters/Catalog/Anderson Anderson promoter collection] J230100-J230119. The plasmid backbone of these biobricks J61002 is very suitable for promoter insertion between the XbaI and SpeI sites, which places the promoter upstream of a red fluorescent protein (RFP)gene. Through the promoter, RFP is expressed more frequently or less, while the promoter strength can easily be characterized via fluorescence measurements.


Our team focused mainly on the second half of the collection, which comprises promoters with the below listed strengths.

Biobrick number Measured relative
promoter strength
BBa_J23119 n/a
BBa_J23101 0.7
BBa_J2308 0.51
BBa_J2309 0.04
BBa_J23111 0.58
BBa_J23112 0.00
BBa_J23113 0.01
BBa_J23114 0.10
BBa_J23115 0.15
BBa_J23116 0.16
BBa_J23117 0.06
BBa_J23118 0.56

We carried out an extended, 18-hour experiment, monitoring cell density through absorbance measurement and promoter strength by way of fluorescence emission. The results are shown subsequently.


Figure1: Absorbance at 700 nm of E. coli DH5&alpha-strains with transformed Anderson promoter familiy members



Please note that we monitored the optical density at 700 nm wavelength, because the UC-Davis team was concerned about interferences of OD600 measurements with the fluorescence measurements.
To determine the relative strength of the used promoters we looked at the fluorescence signal of RFP. With increasing promoter strength, transcription should be enhanced and more RFP will be expressed. This results in a higher fluorescence signal.