Team:Colombia Uniandes/Protocols

From 2013.igem.org

(Difference between revisions)
(Glucocorticoid Sensor)
(GenElute DNA Kit from Sigma-Aldrich with modifications)
Line 23: Line 23:
<li>500 µL of Wash Solution Concentrate (+ ethanol) --> 15000 rpm x 3 min – Discard the collection tube and place the column in a new one.
<li>500 µL of Wash Solution Concentrate (+ ethanol) --> 15000 rpm x 3 min – Discard the collection tube and place the column in a new one.
<li>30 µL of water (miliQ) --> 14000 rpm x 1 min.</li>
<li>30 µL of water (miliQ) --> 14000 rpm x 1 min.</li>
-
<li>30 µL of water (miliQ) 14000 rpm x 1 min.</li>
+
<li>30 µL of water (miliQ) --> 14000 rpm x 1 min.</li>
-
<li>The final eluate contains the DNA – [[Do not discard!]]</li>
+
<li>The final eluate contains the DNA – Do not discard!</li>

Revision as of 02:51, 23 September 2013

Protocol for extraction of yeast genome:

GenElute DNA Kit from Sigma-Aldrich with modifications

  1. 1,5 mL 2 min x 15000 rpm.
  2. 100 µL zymolyase solution.
  3. Vortex.
  4. Incubate 37°C x 30 min.
  5. 180 µL of Lysis Solution T.
  6. 20 µL of Proteinase K.
  7. Incubate 37°C x 30 min.
  8. 200 µL of Lysis Solution C.
  9. Vortex x 15 s.
  10. Incubate 55°C x 10 min.
  11. Column Preperation --> 500 µL Column Preparation Solution --> 13000 rpm x 1 min – Discard the eluate.
  12. 200 µL of ethanol (100%) to the lysate – Vortex. --> Transfer the entire contents of the tube into the binding column --> 12000 rpm x 1 min --> Discard the collection tube and place the column in a new one.
  13. 500 µL of Wash Solution 1 to the column. --> 12000 rpm x 1 min --> Discard the collection tube and place the column in a new one.
  14. 500 µL of Wash Solution Concentrate (+ ethanol) --> 15000 rpm x 3 min – Discard the collection tube and place the column in a new one.
  15. 30 µL of water (miliQ) --> 14000 rpm x 1 min.
  16. 30 µL of water (miliQ) --> 14000 rpm x 1 min.
  17. The final eluate contains the DNA – Do not discard!