Team:UANL Mty-Mexico/Modeling
From 2013.igem.org
Ivanmorales (Talk | contribs) |
|||
Line 108: | Line 108: | ||
<div id="title"> | <div id="title"> | ||
<p><a name="Fixed_temperature_model"><h4>Fixed Temeperature Model <a href="#" class="btn btn-info"><font color="#fff">Back to top</font></a></h4><hr></p></div></div> | <p><a name="Fixed_temperature_model"><h4>Fixed Temeperature Model <a href="#" class="btn btn-info"><font color="#fff">Back to top</font></a></h4><hr></p></div></div> | ||
- | <div class=" | + | <div class="row"> |
+ | <div class="col-md-6"> | ||
<p><b>Steady State</b>: Referrers to the condition or conditions of a physical system or process that does not endure a change over time, or in which any given change is continually balanced by another, such as the stable condition of a system in equilibrium.</p> | <p><b>Steady State</b>: Referrers to the condition or conditions of a physical system or process that does not endure a change over time, or in which any given change is continually balanced by another, such as the stable condition of a system in equilibrium.</p> | ||
<p><b>Parameter estimation</b>: is the process or method used when trying to calculate mathematical model parameters based on experimental data sets through numerical methods. These data sets can be the result of steady states of independent events or time course experiments. Although there are numerical methods to do this, more complex algorithms with great accuracy are already incorporated in most of the new mathematical software, such as COPASI and MATLAB.</p> | <p><b>Parameter estimation</b>: is the process or method used when trying to calculate mathematical model parameters based on experimental data sets through numerical methods. These data sets can be the result of steady states of independent events or time course experiments. Although there are numerical methods to do this, more complex algorithms with great accuracy are already incorporated in most of the new mathematical software, such as COPASI and MATLAB.</p> | ||
- | <p>More deeply, Estimation Theory is a branch of Statistics and Signal processing that deals with estimating the values of parameters based on measured/empirical data that has a random component (deviation or unknown tendency). The parameters describe an underlying physical setting in such a way that their value affects the distribution of the measured data. An estimator attempts to approximate the unknown parameters using the measurements, trying to adjust these parameters to fit the model to the experimental data.</p> | + | <p>More deeply, Estimation Theory is a branch of Statistics and Signal processing that deals with estimating the values of parameters based on measured/empirical data that has a random component (deviation or unknown tendency).</div><div class="col-md-6"> The parameters describe an underlying physical setting in such a way that their value affects the distribution of the measured data. An estimator attempts to approximate the unknown parameters using the measurements, trying to adjust these parameters to fit the model to the experimental data.</p> |
<p>The best numerical method for the estimation of parameters through COPASI resulted to be the Evolutionary Programming.</p> | <p>The best numerical method for the estimation of parameters through COPASI resulted to be the Evolutionary Programming.</p> | ||
Line 119: | Line 120: | ||
<p>Another way to do this parameter estimation, is performing a Function Fit for the analytic solution of the differential equations, which is shown in the Appendix, at the end of this page.</p> | <p>Another way to do this parameter estimation, is performing a Function Fit for the analytic solution of the differential equations, which is shown in the Appendix, at the end of this page.</p> | ||
- | <p>Due to time restrictions, we didn't get time series data for the relative fluorescence at a fixed temperature. This data would have been useful for estimating the parameter /(/delta/) of our dynamic model.</p> | + | <p>Due to time restrictions, we didn't get time series data for the relative fluorescence at a fixed temperature. This data would have been useful for estimating the parameter /(/delta/) of our dynamic model.</p></div></div> |
<div id="title"> | <div id="title"> | ||
<p><a name="Dynamic"><h4>Dynamic Model <a href="#" class="btn btn-info"><font color="#fff">Back to top</font></a></h4><hr></p></div></div> | <p><a name="Dynamic"><h4>Dynamic Model <a href="#" class="btn btn-info"><font color="#fff">Back to top</font></a></h4><hr></p></div></div> |
Revision as of 00:42, 29 October 2013
Mathematical models that represent the dynamic behavior of biological systems are a quite prolific field of work and are pillar for Systems Biology. A number of deterministic and stochastic formalisms have been developed at different abstraction levels that range from the molecular to the population levels.
In principle, a model that is simple but that is good enough to describe and make predictions, with a degree of certainty, about the phenomenon under scrutiny, would be desirable.
Deterministic mathematical models that describe the behavior of genetic circuits and the interactions of the proteins they encode are usually built upon mass action kinetics theory.
Aside from the common objection that they are not suitable to describe systems that show a low number of particles, we believe that a deterministc model at a molecular level of these kind of systems and the degree of certainty with which they can be used for inter-system comparison or usage, do not outweigh the costs of the experimental determination of parameters.
Here we propose a model for the description and comparison of the behavior of the effect of RNA thermometers or RNATs on the expression of a reporter protein. The model is tested with relative fluorescence units data, which are not hard to obtain, and the model and its parameters should allow for inter-system comparisons i.e., to compare the temperature-dependent gene regulation features of different RNATs.
We present a model for the relation between time, temperature and the change in fluorescence (measured in Relative Fluorescent Units or RFUs) of an E. coli culture that harbors a genetic construction where a fluorescent protein is under control of a RNAT.
We expect the temperature to be the main factor involved in the regulation of the reporter gene. In an ideal situation, where temperature is changed over time and where cells are left to reach the maximum fluorescence at each temperature, we expect to first have an off state (basal fluorescence) at low temperatures followed by an increase in the relative fluorescence until an optimum is reached at a certain temperature. Then, we expect to observe a decline until an off state is reached again. Time will have almost the same effect as it does in any other giving biological phenomena involving gene expression.
The relative fluorescence units (RFUs) were calculated in relation to the amount of fluorescence emitted by an E. coli K12 culture transformed with a constitutively expressed part BBa_E1010 (for RFP expression) or BBa_E0040 (for GFP expression) per unit of Optical Density at 600 nm light (OD600) after 17hr of growth at 37°C in LB medium.
All fluorescence measurements were normalised to the OD600 nm of their corresponding culture.
In this way the amount of fluorescence emitted by our culture was calculated as follows:
\begin{equation} \large F_{R} = \frac{F_{sample}}{F_{standard}} \end{equation}where Fsample is the OD600nm-normalised fluorescence emitted by a sample, while Fstandard is the OD600-normalised fluorescence measurement for the corresponding standard culture (again, BBa_E1010 for RFP and BBa_E0040 for GFP).
In our experiments, we had the same unchanging global conditions (temperature, initial conditions, and medium used to grow cells).
For each measurement at a given temperature, the system was left growing until a point in which the OD normalised relative fluorescence reached its saturation point.
After a few exploratory tests at different incubation times, it was found that the optimal incubation time to reach signal saturation was around 15 hours to 20 hours. Taken this into account, all the measurements used for the model were done at 17 hours of incubation time. Thus, we can say these fluorescence measurements were Steady State measurements
Our measurements were made in LB medium at 25, 30, 37 and 42°C, for each one of our constructions that are part of the whole circuit.